background image

4

EN

air cleaner TAC 750 E

Residual risks

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Warning

Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!

Warning

The device is not a toy and does not belong in the
hands of children.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Caution

Risk of injury from parts being whirled up!
Before switching the device on, make sure that there
are no loose parts (clothing, hair ...) located near the
air inlet or outlet!

Note

Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.

Note

Do not use abrasive cleaners or solvents to clean the
device.

Behaviour in the event of an emergency

1. Switch off the device.
2. In an emergency, disconnect the device from the mains

feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.

3. Do not reconnect a defective device to the mains.

Information about the device

Device description

Air cleaners are used to filter the room air. On building sites and
renovation areas high concentrations of dust can arise, for
instance when using angle grinders or during blasting, chiselling
or demolition operations as well as when mixing dry mortar or
tile cement.
Depending on the inserted filter, the air cleaners of the
TAC series serve to eliminate various dusts, e.g. from asbestos,
building rubble, quartz, flour, wood, etc., but also mould spores,
paint particles and mineral fibres in the air, possibly arising
during the above-mentioned operations.
This dust is to be vacuumed off as close as possible to the point
of origin in order to reduce the pollution of the breathing air to a
minimum. Depending on the used filter quality it is permissible
to employ the device for the separation of quartziferous mineral
dusts, wood dust, lead-containing dusts, artificial mineral fibres
or high-temperature fibres.
Application as vacuum generator for mould remediation and
asbestos abatement is also a possibility. In case of other
hazardous substances there are additional requirements; hence
observe the corresponding Technical Rules for Hazardous
Substances (TRGS) or the country-specific regulations.
The device is suited for:

producing a vacuum in a room, e.g. in heavily
contaminated spaces;

air purification in workspaces via air circulation, e.g. indoor
building sites, workshops etc.;

producing overpressure in a room, e.g. cleanroom;

supplying filtered fresh air.

The device is structured as follows:

housing with stacking aid

adjustable fan for air transport

filter monitoring for air volume flow

The device may be equipped with various filters. It provides the
user with the possibility of configuring both the filter quality and
the filter chain arrangement for the respective field of
application. The filters must be selected according to the area of
application.
The device is approvable for asbestos abatement as per
TRGS 519, dust class H.

Info

The filters are not included in the scope of delivery!
Choose the filters according to the area of application
from our filter range. Insert the selected filters prior to
initial start-up.

Summary of Contents for 1.580.000.101

Page 1: ...TRT BA TAC750E TC2018 55 004 EN TAC 750 E EN ORIGINAL INSTRUCTIONS AIR CLEANER...

Page 2: ...manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fir...

Page 3: ...e that the suction side is kept free of dirt and loose objects Dispose of replaced filters properly especially after filtering substances hazardous to health Never use the device as storage place or f...

Page 4: ...on operations as well as when mixing dry mortar or tile cement Depending on the inserted filter the air cleaners of the TAC series serve to eliminate various dusts e g from asbestos building rubble qu...

Page 5: ...f the device Transport Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power ca...

Page 6: ...ing to the area of application from our filter range Insert the selected filters prior to initial start up Prior to start up the filter chain of the device must be configured according to the desired...

Page 7: ...vice 12 7 Insert the HEPA filter 12 into the device 12 8 Put the filter frame 14 back into the device and tighten the knurled screws 13 13 13 14 9 Insert a new coarse or fine filter 9 10 11 into the d...

Page 8: ...iculates or the separation of suspended matter according to EN 60335 2 69 up to dust class H Here the filtration of dust particles and other suspended material harmful and hazardous to health has prio...

Page 9: ...n tools or accessories other than those specified in the instructions may cause a risk of injury Designation Article number G3 spray paint filter 7 160 000 416 G4 Z line filter 7 160 000 404 F7 pleate...

Page 10: ...t remove the filters and the filter frame as described in the Inserting the filters section in the Assembly and start up chapter 2 Clean the inside of the device and the filter frame with a soft damp...

Page 11: ...1376 15 Plug B1140 3 Rotary button P10001250 16 Nut P10000371 4 Fan P10000576 17 Potentiometer P10001751 5 Lock nut P10001248 18 Operating element P10001827 6 Cable bushing P10001247 19 Spacer sleeve...

Page 12: ...The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 42767 Declaration of conformity in accordance with th...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: