Trotec 1.580.000.101 Original Instructions Manual Download Page 3

EN

3

air cleaner TAC 750 E

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The mains connection must correspond to the
specifications in the Technical annex.

Insert the mains plug into a properly secured mains
socket.

Observe the technical data when selecting extensions to
the power cable. Completely unroll the extension cable.
Avoid electrical overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

Make sure that the air inlet and outlet are not obstructed.

Make sure that there are no loose items or dirt located in
the immediate surroundings of air inlet and air outlet.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Make sure that the suction side is kept free of dirt and
loose objects.

Dispose of replaced filters properly, especially after
filtering substances hazardous to health.

Never use the device as storage place or footstep.

Intended use

Only use the device to clean atmospheric air from non-
conducting and non-combustible dusts, fogs or suspended
matter whilst using the appropriate filter classes and adhering
to the technical data.

Foreseeable misuse

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Do not use the device to siphon off vapours or fluids.

Any use other than the intended use is regarded as a
reasonably foreseeable misuse.

Any unauthorised modifications, alterations or structural
changes to the device are forbidden.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electrically driven air cleaners.

have read and understood the instructions, especially the
Safety chapter.

Electrically skilled person

Electrically skilled personnel must be able to read and
understand electric circuit diagrams, to put electrical systems
into service and to maintain them, to wire control cabinets, to
ensure the functionality of electrical components and to identify
possible hazards from electrical and electronic systems.

Instructed person

Instructed persons have been informed of the tasks they were
entrusted with as well as of potential hazards resulting from
inappropriate behaviour. They are allowed to operate and
transport the device and perform simple maintenance activities
(cleaning the housing, cleaning the fan).
The device is to be maintained and looked after by instructed
personnel.

Summary of Contents for 1.580.000.101

Page 1: ...TRT BA TAC750E TC2018 55 004 EN TAC 750 E EN ORIGINAL INSTRUCTIONS AIR CLEANER...

Page 2: ...manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fir...

Page 3: ...e that the suction side is kept free of dirt and loose objects Dispose of replaced filters properly especially after filtering substances hazardous to health Never use the device as storage place or f...

Page 4: ...on operations as well as when mixing dry mortar or tile cement Depending on the inserted filter the air cleaners of the TAC series serve to eliminate various dusts e g from asbestos building rubble qu...

Page 5: ...f the device Transport Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Do not use the power ca...

Page 6: ...ing to the area of application from our filter range Insert the selected filters prior to initial start up Prior to start up the filter chain of the device must be configured according to the desired...

Page 7: ...vice 12 7 Insert the HEPA filter 12 into the device 12 8 Put the filter frame 14 back into the device and tighten the knurled screws 13 13 13 14 9 Insert a new coarse or fine filter 9 10 11 into the d...

Page 8: ...iculates or the separation of suspended matter according to EN 60335 2 69 up to dust class H Here the filtration of dust particles and other suspended material harmful and hazardous to health has prio...

Page 9: ...n tools or accessories other than those specified in the instructions may cause a risk of injury Designation Article number G3 spray paint filter 7 160 000 416 G4 Z line filter 7 160 000 404 F7 pleate...

Page 10: ...t remove the filters and the filter frame as described in the Inserting the filters section in the Assembly and start up chapter 2 Clean the inside of the device and the filter frame with a soft damp...

Page 11: ...1376 15 Plug B1140 3 Rotary button P10001250 16 Nut P10000371 4 Fan P10000576 17 Potentiometer P10001751 5 Lock nut P10001248 18 Operating element P10001827 6 Cable bushing P10001247 19 Spacer sleeve...

Page 12: ...The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 42767 Declaration of conformity in accordance with th...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: