Ozone generator Airozon 60000
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Switch the fuse back on or have a defective fuse replaced
by a specialist company.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is very loud:
•
Position the device on a dry, firm and level surface.
•
Check whether the fan and its bearing for damage. If you
detect any damage, have the device checked by a certified
specialist workshop.
The odour nuisance persists after the completed
purification process with the same intensity:
•
Have the device checked by a certified specialist
workshop.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Make sure that the device is switched off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning
Risk of injury caused by inhalation of ozone!
After the device has stopped operating, wait until the
end of the calculated regeneration period (see
Shutdown chapter) to make sure that the ozone
concentration has fallen below the stipulated value
before performing maintenance and cleaning work.
Care and maintenance must be performed on a regular basis to
ensure the proper functioning and failure-free operation of the
device.
The type and frequency of the maintenance tasks fundamentally
depends on the operating environment as well as on the
duration and type of use.
In the course of using the device, dust and moisture can
accumulate in or on the components which may compromise
functionality and efficiency.
In rooms with a high volume of dust and dirt or after fire
damage restorations (high moisture level) you should already
check the need for maintenance after only a few applications.
In dry surroundings e.g. hotels or as part of car valeting one can
assume a maintenance rate of several months.
Criteria for determining the maintenance interval
Device operation takes place:
•
frequently and several hours at a time
•
on many days per month
•
in excessively dirty surroundings
•
in humid rooms
Regardless of the described operating conditions you should
perform maintenance work if one or more of the following signs
become apparent:
•
increased noise level during operation of the fan
•
heavily contaminated air filter
•
dirty electrode (recognizable by: The hissing sound
produced during ozone generation dies away.)