WARNING : TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY
TO PERSONS, PLEASE OBSERVE THE FOLLOWING :

READ AND SAVE THESE INSTRUCTIONS

P1

1]. To ensure the success of the installation, be sure to read the instructions and review the diagrams

thoroughly before beginning.

2].

All electrical connections must be made in accordance with local codes, ordinances and/or the

National Electric Code. If you are unfamiliar with the methods of installing electrical wiring and

products, secure the services of a qualified and licensed electrician as well as someone who can

check the strength of the supportive ceiling members and make the proper installations and

connections.

3]. Make sure that your installation site will not allow rotating fan blades to come in contact with any

object. Blades should be at least 7 feet from floor when fan is in operation.

4]. If possible, mount ceiling fan on a ceiling joist - the joist must be able to support the motion and weight

of the moving fan. If the fan will be mounted on a ceiling outlet box, a 4" x 2-1/8" deep METAL octagon

box is required ; one UL listed as " suitable for fan support ". The box and its supporting members must

not be able to twist or work loose. DO NOT USE PLASTIC BOXES. Installation on a concrete ceiling should

be performed by qualified personnel.

5]. Blades should be attached after motor housing is hung and in place. Fan motor housing should be

kept in carton until ready to be installed to protect its finish. If you are installing more than one ceiling

fan, make sure that you do not mix fan blade sets.

6]. After making electrical connections, spliced conductors should be turned upward and pushed

carefully up into outlet box. The wires should be spread apart with the grounded conductor and the

equipment - grounding conductor on one side of the outlet box and the " HOT " wires on the other side.

7]. Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL/ETL listed

and should be installed per the light kit's installation instructions.

8]. After fan is completely installed, check to make sure that all connections are secure to prevent fan

from falling and/or causing damage or injury.

9]. The fan can be made to work immediately after installation. The bearings are adequately charged with grease,

so that under normal conditions, further lubrication should not be necessary.

10]. The fan must be turned off and stopped before reversing fan direction.

11].

12].

13].

14].

15]

To avoid possible electric shock, be sure electricity is turned off at the main power box before wiring.

This fan is suitable for three mounting ways: Downrod (standard)/ Flush (Hugger) / Slope ceiling.

This fan is reversible.

This fan is light kit adaptable.

This fan is remote adaptable.

. This fan is suitable for indoor use.

Summary of Contents for 5DA52

Page 1: ...rnings shown throughout 5DA52 This instruction contains 6 pages Page 1 Foreword Page 2 Unpack and inspect parts contained Page 3 Notes before installation Page 3 4 Page 5 C Hanging system installation and Wire connection anopy Blade Switch Housing installation Page 6 Pull Chain Knob installation 3110124 Toll Free 1 855 676 7247 ...

Page 2: ...fied personnel 5 Blades should be attached after motor housing is hung and in place Fan motor housing should be kept in carton until ready to be installed to protect its finish If you are installing more than one ceiling fan make sure that you do not mix fan blade sets 6 After making electrical connections spliced conductors should be turned upward and pushed carefully up into outlet box The wires...

Page 3: ... For Blade Installation Blade Screw x 21 one spare screw included Flat Washer x 21 one spare washer included Motor Screw x 11 one spare screw included For Fan Pull Chain Knob x1 For Blade Balance Balancing slide x 1 Weight block 3G x 3 3 GM 3 GM 3 GM Canopy Set Screw x 4 Spring Washer x 4 For Canopy Installation For Flush Mount O ly n Canopy Set Screw x 3 For Mounting Bracket Flat Washer x2 Spring...

Page 4: ...rod mount Flush mount 1C Downrod and Yoke Installing Remove cross pin and cotter pin from downrod Insert downrod through canopy and yoke cover and feed motor lead wires through downrod Loosen 2 downrod jam screws at yoke Insert downrod assembly into yoke Insert the cross pin through yoke downrod and secure with cotter pin Tighten both downrod jam screws to further secure downrod Pull down the yoke...

Page 5: ... canopy set screws provided from hardware bag onto fan assembly firmly 1 2 Follow diagram below and make sure that all exposed wires are secured inside wire nuts or terminal block Note Wires from house may vary in color and may not include ground wire green From House White Black From Fan White Black AC N AC L MOTOR N MOTOR L Green Green Green from downrod from mounting bracket for ground wire Whi...

Page 6: ...lade Screw 4 Blade Holder Flat Washer 4 1 Push up the canopy till center hole of canopy is engaged with spring tab of mounting bracket Secure canopy to mounting bracket with four canopy set screws and provided from hardware bag for further security Spring Washers 1 2 Motor screw 2 3 Motor Stopper 3 2 Blade Assembly Fan assembly Mounting Bracket Canopy Spring Washer 4 Switch Housing Cover 1 5 INSTA...

Page 7: ...wer at breaker box your fan is ready for operation Pull Chain Knob Connect Pull Chain Knob provided from hardware bag to the pull chain from switch housing 6 PULL CHAIN KNOB INSTALLATION Fan Assembly Switch Housing P6 ...