Once your Fire Pit has been converted to Natural Gas, please locate the small silver label and 

remove the bottom strip.  Place this strip over the section indicated above, on the large label 

located on the inside door. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R9T12FIRE 

Page 14 of 16 

Rev. H 06SEP17 

 

 

 

Once your Fire Pit has been converted to Natural Gas, please locate the small silver label and 

remove the bottom strip.  Place this strip over the section indicated above, on the large label 

located on the inside door. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

305251_R9T12FIRE.indd   14

9/14/17   2:18 PM

Summary of Contents for 401400RD Series

Page 1: ...or death and may result in property damage Read these installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors or liquids in or near this or any other appliance An LP Liquefied Petroleum tank that is not connected for use shall not be stored in or near this or any other appliance If y...

Page 2: ...stitute NFI as NFI Gas Specialist or by the Wood Energy Technical Training WETT R9T12FIRE Page 2 of 16 Rev H 06SEP17 INSTALLATION Tropitone recommends that all gas products be installed by professionals that are licensed by the local authority having jurisdiction in gas piping MAINTENANCE Tropitone recommends that all gas products installed in the USA and CANADA be serviced and maintained by profe...

Page 3: ...ral and LP produces fumes which can be dangerous if inhaled Always insure there is proper ventilation when using any fire products DANGER All Fire Pits are designed and intended for outdoor use only Never install or operate indoors Burning gas both Natural and LP produces very high temperatures Always insure all combustible materials are kept far enough away to prevent accidental ignition IMPORTAN...

Page 4: ...or use with all types of gas Apply to all male pipe fittings only DO NOT use on FLARED fittings Be sure all joints are tightened securely before lighting WARNING Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative tha...

Page 5: ...tical LP gas tank in place of a horizontal LP gas tank in 401700RCT base models R9T12FIRE Page 5 of 16 Rev H 06SEP17 WARNING The LP Gas tank or cylinder used must comply with the following requirements Use of other tanks or cylinders which do not meet these requirements may create an unsafe condition which could cause injury or death to you or damage to your personal property including the risk of...

Page 6: ... the case and insert back into original location Battery Case of 9 volt battery R9T12FIRE Page 6 of 16 Rev H 06SEP17 You can now connect your LP gas tank to the Fire Pit using the standard propane gas hose with built in regulator shown in blue Hand tighten the propane tank gas connector shown in black to the tank valve shown in red CAUTION Do NOT use tools to tighten this connection Open the gas v...

Page 7: ...rn off pit or delay main burner ignition Lava rock not available from Tropitone R9T12FIRE Page 7 of 16 Rev H 06SEP17 FIRE MEDIA INSTALLATION Please follow the instructions below to add the finishing touch to your Fire Pit Your Fire Pit needs fire media in order to get the proper flame characteristics from the burner assembly The media can be decorative fire glass fire pebbles lava rock or other fi...

Page 8: ...has cooled completely use appropriate cover sold separately to protect Fire Pit R9T12FIRE Page 8 of 16 Rev H 06SEP17 LIGHTING INSTRUCTIONS To light your new Fire Pit complete all installation and safety instructions above Be sure to install a 9 volt battery in the ignition system battery case mounted on the inside post of the right door frame To install the battery follow the instructions on page ...

Page 9: ...7FPSGV 13 9V Ignition Power Supply R19NT111 14 9V Battery Box 16 Leads R19NT112 R9T12FIRE Page 9 of 16 Rev H 06SEP17 INTERNAL CONTROLS 401400RD 401400SQ 401700RCT BASE PARTS LIST Item No 1 Description Ignition Switch With Gasket Part No R19SW100 2 Gas Valve R18VL100 3 Nut Retaining M1 for Gas Valve R02NU501 4 Knob Black for Gas Valve R02MS102 5 Gas Flex Line 24 x 1 2 R15SP100 6 Nipple 3 8 x 1 5 R1...

Page 10: ...iter Assembly R19NT100 6 Nut 1 2 Stainless Steel R02NU500 7 Burner Tray Round 18 R15MS300 Burner Tray Square 18 not shown R15MS301 8 Washer 1 50 OD x 0 0890 ID x 0 09 R02WA880 9 Nipple 1 2 Stainless Steel R15CO106 10 1 2 FPT x 3 8 FPT 90 Reducing Elbow R18CO120 11 3 8 LP Gas Air Mixer R18VL101 12 Solid Hex Socket Plug W Thread Sealant R02SC443 13 1 2 MPT x 1 8 FPT Reducing Bushing R15CO110 14 1 2 ...

Page 11: ...ermocouple Assembly R19TC100 6 Igniter Assembly R19NT100 7 Burner Support R15MS309 8 Burner Tray 30 x 8 Rectangular R15MS308 9 Washer 1 Stainless Steel R02WA880 10 Nipple 1 2 Stainless Steel R15CO106 11 1 2 FPT x 3 8 FPT 90 Reducing Elbow R18CO120 12 3 8 LP Gas Air Mixer R18VL101 13 Flare x 3 8 MIPT R18CO107 14 3 8 FPT TEE R15CO109 15 1 2 MPT x 1 8 FPT Reducing Bushing R15CO110 16 Solid Hex Socket...

Page 12: ...beneath the burner tray When converting from LP to Natural gas installer must remove the supplied gas hose and LP regulator and install the correct regulator for Natural gas The regulator must limit the supply as specified below Natural Gas Supply Pressure Minimum 5 0 WC water column Maximum 10 0 WC Operating Pressure Minimum 5 0 WC Maximum 7 0 WC Remove the LP Gas tank hose from the gas valve sho...

Page 13: ...r and replace with the Natural Gas Orifice LP Gas Air Natural Mixer Gas Orifice R9T12FIRE Page 13 of 16 Rev H 06SEP17 CAUTION Use a joint compound or thread tape approved for the type of gas this appliance is intended to use on all male threads EXCEPT compression threads Never apply thread tape of compound to compression threads Beneath the Burner tray locate the Gas Air Mixer in the plumbing Remo...

Page 14: ... over the section indicated above on the large label located on the inside door R9T12FIRE Page 14 of 16 Rev H 06SEP17 Once your Fire Pit has been converted to Natural Gas please locate the small silver label and remove the bottom strip Place this strip over the section indicated above on the large label located on the inside door K 305251_R9T12FIRE indd 14 9 14 17 2 18 PM ...

Page 15: ...pitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2015 R9T12FIRE Page 15 of 16 Rev H 06SEP17 This Fire Pit has been tested and approved in accordance with ANSI Z21 97 by ICC ES Listing No PMG 1114 Tropitone Furniture Co Inc 5 Marconi Irvine Ca 92618 949 951 2010 www tropitone com 1401 Commerce Blvd Sarasota Fl 34243 Tropitone Furniture Co Inc 2015 K 305251_R9T12FIRE indd 1...

Page 16: ...R9T12FIRE Page 16 of 16 Rev H 06SEP17 K 305251_R9T12FIRE indd 16 9 14 17 2 18 PM ...