Model: 5731
Hydraulic Power Unit
08/2016 | Rev. 08
Page | 47
9.13
ADDITIONAL FEATURES (
continued
)
9.13.3
Voltage/Phase Monitor
(Options H
J)
The Voltage/Phase Monitor does not require regular general maintenance. The panel indicator light will illuminate if a tripped
condition exists. If the Voltage/Phase Monitor is causing the HPU to shut off, verify the
Phase Monitor settings shown.
Continued tripping may indicate a serious electrical problem. See Section
10.0
Provision of Spares
for recommended
spare fuses.
NOTE: Wire per Electrical Schematic INS-1608. Reference Wiring Diagram INS-1597. Reference Section 9.7.1
Electrical Panel for Panel Light.
PARTS LIST
Item
Part Number
Description
Qty
1 ............................ EC-1541-01 ..................................... Fuse Holder, IEC Class CC ...................................................... 3
2 ............................ EC-1675-12 ..................................... Fuse, KTK-R, 2 amp................................................................. 3
3 ............................
See Table below
.............................. Phase Monitor .......................................................................... 1
Phase Monitor
Option
Voltage
Frequency
Part Number
H
380
50/60 Hz
EC-1543-03
I
415
460
50/60 Hz
EC-1543-04
J
575
60 Hz
EC-1543-05
Setting Instructions for Item 3:
1. Set
Line Voltage
to match the voltage rating of the Hydraulic Power Unit.
2. Set
% Voltage Unbalanced
to 5% for 60 Hz unit or 6% for 50 Hz unit.
3. Set
Trip Delay
to three (3) seconds.
FIGURE 9.13.3
Voltage/Phase Monitor
Summary of Contents for 5731
Page 55: ...Model 5731 Hydraulic Power Unit 08 2016 Rev 08 Page 50 This page left blank intentionally...
Page 66: ......
Page 67: ...APPENDIX I Declaration Of Conformity...
Page 68: ......
Page 70: ......
Page 71: ...APPENDIX II Hydraulic Schematic INS 1660...
Page 72: ......
Page 73: ...APPENDIX III Electrical Schematic INS 1608 INS 2016...
Page 74: ......
Page 75: ...APPENDIX IV Wiring Diagram INS 1597 INS 2046...
Page 76: ......
Page 77: ...APPENDIX IV Lincoln Motor Manual...
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ...APPENDIX V Oilgear Pump Manual...
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ...APPENDIX VI Material Safety Data Sheet MSDS Hydraulic Fluid...
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ...APPENDIX VII ANSI B93 19M 1972 R1993 Excerpt...
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ...APPENDIX VIII Instrument Certification Notice...
Page 118: ......