Page 2    September 2010    Installed in exposed T 35 profiles in removable, suspended ceiling system

STORAGE AND ACCLIMATISATION

Product name

Perimeter angle profile, V300 – 30× 30 mm

Cross tee, T60 – 24× 38 mm

Main tee profile, B360 – 24 × 38 mm

Length (mm)

3000

600

3600

Quantity per pack

40 pcs

40 pcs

15 pcs

Approx. qty. per m

2

According to measurement

600 ×1200 cm : 1.4 pcs. 

600 ×600cm : 2.8 pcs.

1.7 linear m

Product name

Perimeter angle profile, S300 – 22 + 11/9 + 19 mm

Adjustable hanger

Length (mm)

3000

180 - 300 / 300 - 600 / 600- 1000

Quantity per pack

40 pcs

100 pcs

Approx. qty. per m

2

According to measurement

1.4 pcs

COMPONENTS

°C

%RF

°C

%RF

Outdoor storage

If it is necessary to store Troldtekt panels 
outdoors, you should protect the panels 
using a tarpaulin or similar. Please note 
that outdoor storage should be as brief 
as possible and never directly on the 
ground.

Indoor storage

If you store Troldtekt panels indoors, you 
must remove any packaging, as condensa-
tion could otherwise form within the pack-
aging. Care should be taken to protect 
stored Troldtekt panels from moisture, 
 direct heat and dust.

Acclimatisation

It is important that the Troldtekt panels 
are allowed to acclimatise prior to installa-
tion. Acclimatisation means that the 
 panels must adapt to the temperature 
and moisture in the room where they are 
to be installed. 

Reviews: