VII. Maintenance
The Trodat Flash Machine T1511M has been designed for low maintenance operation as well
as ease of use. There are regularly scheduled maintenance requirements consisting of
cleaning the glass and machine body as needed. Please observe the following cleaning tips.
Cleaning the exposure glass
Unplug the unit for 10 minutes before performing any operations below. It is very important to
keep the glass in the exposure area clean and dust free. This will prevent any possibility of
foreign objects interfering with producing a properly exposed die box or foam. Clean the glass
with any household glass cleaner. Apply glass cleaner to a soft paper towel and then use the
towel to clean the glass. Do not spray any cleaners directly on the glass or any other part of
the machine.
Cleaning the machine body
Unplug the unit for 10 minutes before performing any operations below. Apply water or any
mild household cleaner if needed to a soft towel and wipe the surface of the machine clean.
The towel should be damp, not wet. Do not use any solvent based cleaners to clean the unit,
this may cause damage to the paint or display.
VIII. Technical specification
Flash Stamp Machine Model:
T1511M
Quantity of lamps:
3
Exposure area:
150mm x 110mm
Dimension:
340mm x 235mm x 187mm
Weight:
9,7kg
AC power supply:
220-240 V
Frequency:
50/60 Hz
Power consumption:
1200 W