Programming table of the most important CVs
CV Designation
Meaning
Area
Factory setting
29
Configuration register
0, 1, 2, 3, 4,
4
5, 6, 7, 16, 17,
18, 19, 20, 21,
22, 23, 32, 33,
34, 35, 36, 37,
38, 39, 48, 49,
50, 51, 52, 53,
54, 55
49
Expanded configuration
Additional setting options.
0, 1, 32, 33
33
Total value must be calculated.
Total value = value of bit0 + value of bit6
63
Noise volume
0 = soft, 1 = medium, 2 = loud
0, 1, 2
2
Bit Function
Val.
2
Analog operation not possible
0
Analog operation possible
4
4
Engine characteristic
0
defined by CV 2, 5, 6
Engine characteristic
16
defined by CV 67 – 96
5
Short address (CV 1) active
0
Long address (CV 17 + 18)
32
active
Bit
Function
Val.
0
Load regulation off
0
Load regulation active
1
5
No automatic
0
DCC speed level detection
Automatic
32
DCC speed level detection
Blocked list: The following CVs must not be
7, 9, 11, 13, 14, 23, 24, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42,
changed under any circumstances:
43, 44, 45, 46, 47, 48, 56, 57, 58, 60, 66, 95, 113, 114, 115, 121