background image

5

Function 

•   This model is designed for operation with H0 2-rail DC sys-

tems (track according to NEM standards) with conventional 

DC power packs (12 volts). 

•   This locomotive is equipped with an electrical interface  

connection for digital operation and can be retrofitted with 

the 66849 Selectrix locomotive decoder.

•   Headlights change over with the direction of travel.
•   The special motor and gear train are maintenance free.
•  A smoke generator can be retrofitted to the locomotive - also 

for analog operation.

The necessary maintenance that will come due with normal 

operation is described below. Please see your authorized TRIX 

dealer for repairs or spare parts. 

Safety Information 

•  This locomotive is only to be used with the operating system 

it is designed for.

•  This locomotive must not be supplied with power simultane-

ously by more than one power source.

•  Please make note of the safety information in the instructions 

for your operating system.

•   The feeder track must be equipped to prevent interference with 

radio and television reception, when the locomotive is to be run 

in conventional operation. The 611 655 interference suppression 

set is to be used for thispurpose. The interference suppression 

set is not suitable for digital operation.

No warranty or damage claims shall be accepted in those cases where 

parts neither manufactured nor approved by Trix have been installed in 

Trix products or where Trix products have been converted in such a way 

that the non-Trix parts or the conversion were causal to the defects and / 

or damage arising. The burden of presenting evidence and the burden of 

proof thereof, that the installation of non-Trix parts or the conversion in or 

of Trix products was not causal to the defects and / or damage arising, is 

borne by the person and/or company responsible for the installation and / 

or conversion, or by the customer.

WARNING!

 This product contains magnets. Swallowing more 

than one magnet may cause death in certain circumstances. 

If necessary, see a doctor immediately.

Summary of Contents for 040D Series

Page 1: ...Modell der Serie 040D 22369...

Page 2: ...ichsbahn Selbst nach 1945 waren noch ber 1 000 Lokomotiven im Einsatz die in beiden Teilen Deutsch lands noch Dienst taten Information about the Prototype The class G 8 1 Prussian freight steam locomo...

Page 3: ...eichsbahn M me apr s 1945 il restait encore plus de 1 000 lo comotives en service utilis es tant en Allemagne de l Ouest qu en Allemagne de l Est Informatie van het voorbeeld De Pruisische goederentre...

Page 4: ...hten Sie unbedingt die Sicherheitshinweise in der Gebrauchsanleitung zu Ihrem Betriebssystem F r den konventionellen Betrieb der Lok muss das Anschluss gleis entst rt werden Dazu ist das Entst rset 61...

Page 5: ...structions for your operating system The feeder track must be equipped to prevent interference with radio and television reception when the locomotive is to be run in conventional operation The 611 65...

Page 6: ...fois Il est imp ratif de tenir compte des remarques sur la s curit d crites dans le mode d emploi de votre syst me d exploitation Pour l exploitation de la locomotive en mode conventionnel la voie de...

Page 7: ...t de loc dient de aansluitrail te worden ontstoort Hiervoor dient men de ontstoor set 611 655 te gebruiken Voor het digitale bedrijf is deze ontstoor set niet geschikt Lees ook aandachtig de veilighei...

Page 8: ...e los avisos de seguridad indicados en las instrucciones correspondientes a su sistema de funcionamiento Para el funcionamiento convencional de la locomotora deben suprimirse las interferencias en la...

Page 9: ...sorgente di potenza Vogliate osservare assolutamente le avvertenze di sicurezza nelle istruzioni di impiego del Vostro sistema di funzionamento Per il funzionamento tradizionale della locomotiva il bi...

Page 10: ...N r den motorf rsedda lokdelen ska k ras med konventionell drift m ste anlutningsskenan vara avst rd Till detta anv nder man anslutningsgarnityr 611 655 med avst rning och ver belastningsskydd Avst rn...

Page 11: ...digheder opm rksom p de sikker hedshenvisninger som ndes i brugsanvisningen for Deres driftssystem Ved konventionel drift af lokomotivet skal tilslutningssporet st jd mpes Dertil skal anvendes st jd m...

Page 12: ...les attelages et les pi ces de nition Koppelingen of extra delen bevestigen Encajar los enganches o los accesorios suplementarios Innesto dei ganci o di parti di completamento Koppling eller tillsatsd...

Page 13: ...n auswechseln Changing traction tires Changer les bandages d adh rence Antislipbanden vervangen Cambio de los aros de adherencia Sostituzione delle cerchiature di aderenza Slirskydd byts Friktionsring...

Page 14: ...ately 40 hours of operation Graissage apr s environ 40 heures de marche Smering na ca 40 bedrijfsuren Engrase a las 40 horas de funcionamiento Lubri cazione dopo circa 40 ore di funzionamento Sm rjnin...

Page 15: ...pas lubri er De speciale motor en de aandrijving zijn onderhoudsvrij A U B niet oli n El motor de alta potencia y los engranajes no necesitan manu tenci n Por favor no engrasar Il motore di elevate pr...

Page 16: ...16 Schleifer auswechseln Changing pickup shoes Changer les frotteurs Slepers vervangen Cambio del pat n Sostituzione del pattino Sl psko byts Sl besko udskiftes...

Page 17: ...17 Geh use abnehmen Removing the body Enlever le bo tier Kap afnemen Retirar la carcasa Smontare il mantello K pan tas av Overdel tages af...

Page 18: ...maximal halb mit Rauch l gef llt sein Im Rauchgenerator darf sich keine Luftblase be nden Der Anschlussdraht an der Unterseite des Rauchgenerators muss sicheren Kontakt zur Anschlussfeder im Lokomoti...

Page 19: ...cartucho El hilo tomacorriente de la base debe tener un buen contacto con el resorte que est en el bastidor de la locomotora Potenziali origini di guasti nel caso dell apparato fumogeno L apparato fum...

Page 20: ...20 22 23 21 24 43 37 44 40 36 29 28 35 31 32 30 30 33 17 26 25 26 27 34 35 45 44 39 36 46 28 42 2 1 10 7 5 8 6 4 11 9 3 42 41 38 43 49 47 48 53 51 50 52 17 18 19 Details der Darstellung k nnen von dem...

Page 21: ...23 Linse 761 600 24 Lichtk rper 205 996 25 Antriebswelle 206 004 mit 26 Kalottenlager 257 170 27 Traggestell 143 635 28 Puffer 761 720 29 Haken 282 390 30 Druckfeder 214 330 31 Treibradsatz mit Haftr...

Page 22: ...22 54 57 56 59 58 64 18 52 65 29 28 70 21 72 71 72 74 75 73 72 69 67 68 16 18 55 71 63 61 60 62 19 19 66 Details der Darstellung k nnen von dem Modell abweichen...

Page 23: ...hraube 786 750 62 Kurzschlussstecker 100 993 63 Leiterplatte Beleuchtung 144 558 64 Abdeckung 205 971 65 Kupplungsdeichsel 298 030 66 Zylinderansatzschraube 753 140 67 Tenderunterteil 143 334 mit 68 T...

Page 24: ...Trix Modelleisenbahn GmbH Co KG Stuttgarter Str 55 57 73033 G ppingen 145061 0709 HaEf nderungen vorbehalten Trix Modelleisenbahn GmbH Co KG...

Reviews: