Triton ZENICA 8.5kW Installation And Operating Instructions Manual Download Page 2

2

Zenica

Products manufactured by Triton are safe and without risk provided they are 

installed, used and maintained in good working order in accordance with our 

instructions and recommendations.

W

ARNING:

 

DO NOT

 operate shower if frozen, or suspected of being frozen. 

It must thaw out before using.

D

O NOT

 operate the unit if the shower head or spray hose becomes damaged.

D

O NOT

 restrict flow out of shower by placing shower head in direct contact

with your body.

D

O NOT

 operate the shower if water ceases to flow during use or if water has 

entered inside the unit because of an incorrectly fitted cover.

W

ARNING:

 If restarting the shower immediately after stopping, be aware

that a slug of hot water will be expelled for the first few seconds.

T

he shower head must be descaled regularly.

F

it only shower heads recommended by the manufacturer and never fit any 

additional device to restrict the water outlet flow.

T

he outlet must not be connected to any tap or fitting other than those specified.

T

his appliance is intended to be permanently connected to the water mains and

not connected by a hose set.

A

 suitable double pole isolation switch for supply disconnections must be 

incorporated in the fixed wiring circuit in accordance with current wiring rules.

See Electrical Installation section for further details.

Mains water pressure only.

Minimum inlet pressure 100kPa (1 bar)  150kPa (1.5 bar)  for 10.5kW

Maximum inlet pressure 1000kPa (10 bar)  

  

This book contains all the necessary fitting and operating instructions for 

your electric shower.
Care taken during the installation will provide a long, trouble-free life from 

your shower.

PLEASE READ THIS IMPORTANT SAFETY INFORMATION

INTRODUCTION - PLEASE READ

WARNING

T

his appliance can be used by children aged from 

3

 years and 

above and persons with reduced physical, sensory or mental 

capabilities or lack of experience 

and

 knowledge if they have 

been 

given supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards involved. 

C

hildren may not play with the appliance. 

C

leaning and user 

maintenance shall not be made by children.

Summary of Contents for ZENICA 8.5kW

Page 1: ...ed person in the sequence of this instruction book IMPORTANT SAFETY ADVICE The shower unit MUST BE switched off at the isolating switch when not in use This is a safety procedure recommended for all e...

Page 2: ...fitting other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for supply disconn...

Page 3: ...mply with Water Regulations Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply pipe m...

Page 4: ...erate at a constant rate at your chosen power setting It is the flow rate of the water passing through the heater unit which determines the shower temperature at any given setting the slower the flow...

Page 5: ...12 Plumbing connections 13 Electrical connections 14 Replacing the cover 15 Commissioning 16 Operating the shower 17 18 Operating functions 19 Instructions for installers and service engineers only 20...

Page 6: ...element assembly 7 Pressure switch assembly 8 Stabilising valve 9 Terminal block 10 Earth connection 11 Solenoid valve 12 Water inlet 13 Outlet temperature limiter 14 Pressure relief device PRD 15 Tr...

Page 7: ...ation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket outlet lighting circu...

Page 8: ...bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those rooms must...

Page 9: ...be necessary to select a low power setting to achieve your preferred shower temperature The water supply can be taken from a cold water storage cistern provided there is a minimum head of ten metres a...

Page 10: ...NOT operate the shower with a damaged or kinked shower hose or a blocked shower head which can cause the PRD to operate When commissioning the shower head must be removed from the flexible hose while...

Page 11: ...from the back Note Deviations from the designated entry points will invalidate product approvals If a bottom entry has been chosen the cut out pipe entry on the bottom trimplate should be removed fig...

Page 12: ...n plastering over the pipework in order to make the nut accessible for future adjustments After choosing the site for the shower use the backplate as a template and mark the two fixing holes fig 10 Dr...

Page 13: ...he connection of the water supply to the inlet of the shower and in compliance with Water Regulations flush out the pipework to remove all swarf and system debris To do this connect a hose to the pipe...

Page 14: ...cable earth conductor must be sleeved The outer sheath of the supply cable must be stripped back to the minimum The supply cable must be secured either by routing through conduit or in trunking or by...

Page 15: ...ove the cover and position the temperature control knob so that it points to the 1 position fig 14 Position the power selector to the STOP position fig 15 Replace the cover squarely to the backplate a...

Page 16: ...the electric supply to the shower at the isolating switch The power indicator will light Switch the power selector to the COLD position fig 18 and wait until water starts to flow from the flexible ho...

Page 17: ...PERATURE Single red symbol is the economy setting for using less power during warmer months Temperature adjustment at this setting is via the temperature control Note If the stated flow rate required...

Page 18: ...r temperature Turn the temperature control anti clockwise fig 21 this will increase the flow of water through the shower and is indicated by the lower numbers To increase the shower temperature Turn t...

Page 19: ...overheat temperature is sensed power to the elements will be reduced Water will continue to flow When the temperature has cooled sufficiently power to the elements will be automatically restored to th...

Page 20: ...e the trimplate and disconnect and remove the compression fitting Also depending on the incoming pipework arrangements and if there is not enough slack in the pipework it may be necessary to remove th...

Page 21: ...ch wire assembly P07810903 4 Can assembly 8 5kW P07810708 Can assembly 9 5kW P07810709 5 Stabiliser valve assembly P07810800 6 Solenoid valve assembly 83300450 7 Outlet pipe PRD S07811003 8 Pressure R...

Page 22: ...2 1 Have unit checked Contact Customer Experience 2 1 1 Increase flow rate via temperature control 2 1 2 Blocked shower head clean or replace blocked sprayplate in shower head 2 2 1 Check if stop valv...

Page 23: ...repairs to the shower should be carried out by a suitably qualified person In the unlikely event of a fault occurring please contact Customer Experience Do not remove the shower from the installation...

Page 24: ...ners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verif...

Reviews: