T90xr pumped electric shower
Outline of bath,
shower tray
or cubicle
Cold water supply
from cistern
(top, bottom or back)
Shower can
be mounted
either side of
the riser rail
Ceiling
Height of
showerhead
and shower
to suit user’s
requirement
Shower unit
must not
be within
an area
1 metre
from base
Fig.
Diagrammatic view (not to scale)
W-008-A
WARNING!
The shower must not be positioned
where it will be subjected to freezing
conditions.
SITING oF THe SHoWeR
IMPORTANT:
If installing onto a tiled wall
always mount the unit on the surface of the
tiles. nEVER tile up to the unit.
Refer to
fig.
for correct siting of the shower.
Position the unit where it will nOT
be in direct
contact with water from the showerhead.
Position the shower unit vertically.
Allow enough room between the ceiling and the
shower to access the cover top screws.
Note:
Water regulations require the showerhead
be
‘constrained by a fixed or sliding attachment
so that it can only discharge water at a point
not less than 25 mm above the spill-over level
of the relevant bath, shower tray or other fixed
appliance’
. The use of the supplied soap dish will
in most cases meet this requirement, but if the
showerhead can be placed within a bath, basin
or shower tray, then a double check valve, or
similar, must be fitted in the supply pipework to
prevent back-flow.
Allow enough room between the ceiling and the
shower to access the cover top screws.
Pressure relief safety device
A pressure relief device (PRD) is designed into
the shower unit which complies with European
standards. The PRD provides a level of appliance
protection should an excessive build up of
pressure occur within the shower.
Do not operate the shower with a damaged
or kinked shower hose, or a blocked
showerhead which can cause the PRD to
operate.
When commissioning, the showerhead must be
removed from the flexible hose. Failure to follow
this procedure may also result in causing the
PRD to operate.
Make sure the shower is positioned over a bath
or shower tray because if the PRD operates, then
water will eject from the bottom of the unit.
Should this happen, turn off the electricity and
water supplies to the shower at the isolating
switch and stopvalve. Contact Customer Service
for advice on replacing the PRD.
Two PRD screws
PRD
Outlet pipe
Two outlet
pipe screws
Fig.
Summary of Contents for T90xr
Page 25: ...23 T90xr pumped electric shower ...
Page 26: ...24 T90xr pumped electric shower ...