T90xr pumped electric shower
oPeRATING FUNCTIoNS
Power on indicator
(fig.)
The power neon will light when the electrical
supply to the unit is switched on. This indicates
that power is on to the pump and power
selector.
Low water pressure cut-out
Should the water pressure fall below the
minimum required to operate the shower, power
will be switched off to the heating elements
preventing any maintained temperature rises.
overheat cut-out
During normal operation if an overheat
temperature is sensed, power to the elements
will be reduced. Water will continue to flow.
When the temperature has cooled enough,
power to the elements will be automatically
restored to the setting at the time of
interruption.
Safety cut-out
The unit is fitted with a non-resettable over-
temperature safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.
CLeANING
Triton Plc recommends that all products are
cleaned using warm, soapy water.
DO nOT use abrasive or aggressive chemical
cleaning products as this may affect the product
surface finish and invalidate your guarantee.
T00435
3RZHURQ
LQGLFDWRU
Fig.
WARNING!
DO NOT use abrasive or aggressive
cleaning products when cleaning the
shower as they may damage the unit.