T550i
5
ELECTRICAL REQUIREMENTS
The pump must be connected to a 230 – 240V
A.C. electrical supply, via a double pole switch
with at least 3mm contact separation. This can
be a ceiling mounted pull cord switch in the
shower room, or a wall mounted switch in an
adjacent room.
The pump installation should be fused at 3
amps.
It is recommended that a suitable residual
current device (RCD) is fitted in the electricity
supply circuit to this appliance.
Note:
The installation and wiring must comply
with current IEE regulations.
When installed in any room containing a fixed
bath or shower, the pump MUST be located and
concealed inside a suitable cupboard, built-in
unit or other enclosure, in order so the pump
cannot be sprayed with water, and such that
a person using a fixed bath or shower cannot
touch the pump without using tools.
WARNING!
THE PUMP MUST BE EARTHED.
SITING OF THE PUMP
The pump MUST ALWAYS be positioned
BELOW the cold water cistern and be situated
as close as possible to the hot water cylinder.
It is recommended that the cold water supply
is taken from the opposite side of the cistern
to the float operated valve to prevent air
entrapment in the supply.
Position the pump in a dry area and ensure it is
accessible for any maintenance etc. that may be
necessary.
IMPORTANT: Ensure the ventilation slots on
the underside of the pump are free from
obstructions.
The hot water supply MUST NOT exceed 65°C
(149°F).
WARNING!
THE UNIT MUST NOT BE POSITIONED
WHERE IT WILL BE SUBJECT TO FREEZING
CONDITIONS.