T550i
3
KEY TO MAIN COMPONENTS
Pump (fig.1)
1
Inlet connector hose
2
Outlet connector hose
Integral flow switch
4
Variable speed control
5
PCB cover
Fig.1
Page 1: ...Installers please note these instructions are to be left with the user 2180149I February 2009 Installation and operating instructions T550i power shower pump...
Page 2: ...pump 5 Installation 6 Variable speed control 9 Commissioning 9 Spare parts 11 Fault finding 12 Guarantee Service Policy Etc Rear cover To check the product suitability for commercial and multiple ins...
Page 3: ...tted on the hot and cold water supplies to the pump as an independent means of isolating the water supplies should maintenance or servicing be necessary DO NOT use stop taps or ball o fix type valves...
Page 4: ...ur installation SAFETY WARNINGS a Under no circumstances must this pump be connected to a mains cold water supply Failure to comply will invalidate the guarantee b The shower pump MUST NOT be used if...
Page 5: ...T550i 3 KEY TO MAIN COMPONENTS Pump fig 1 1 Inlet connector hose 2 Outlet connector hose 3 Integral flow switch 4 Variable speed control 5 PCB cover Fig 1 1 1 2 2 3 5 4 3...
Page 6: ...as long as it is the first draw off below the ventilation pipe tee THE PUMP MUST NOT BE CONNECTED TO THE MAINS COLD WATER SUPPLY DO NOT connect into the rising vent pipework The pump must be positione...
Page 7: ...in unit or other enclosure in order so the pump cannot be sprayed with water and such that a person using a fixed bath or shower cannot touch the pump without using tools WARNING THE PUMP MUST BE EART...
Page 8: ...er valves must be fitted immediately prior to the pump It is also advisable to fit a drain off point on the lowest part of the system NEVER use any form of soldered fittings on the shower pump as this...
Page 9: ...til the commissioning procedure has been completed Note Do not overtighten the connections on the pump ports and take care to prevent any system debris from entering the pump via the connectors Wiring...
Page 10: ...over ensure the O ring fig 10 is correctly seated before replacing the control knob WARNING Installation of the pump will break the earth continuity of the pipework installation It is important that t...
Page 11: ...to flow to waste for two or three minutes to ensure any installation debris and air is completely flushed from the system 5 Check the system pipework for leaks 6 Close both isolating valves Remove the...
Page 12: ...Note If care has been taken to prevent any obvious debris entering the system the above procedure should be adequate for normal operating conditions of the pump and shower However it may be advisable...
Page 13: ...bly T550i00M 2 Cover 7052286 3 Impeller housing 7051544 4 Pump inlet 7051543 5 Speed control knob 7051552 6 End cap 7052310 7 PCB assembly 7072314 8 Flow switch assembly 82300700 9 Flexible connector...
Page 14: ...heck all connections and secure where necessary 1 4 1 Check isolating valve is fully open 1 4 2 Check head of water 1 4 3 Ensure inlet filter is clean 1 5 1 Replace switch Contact Triton Customer Serv...
Page 15: ...T550i 13...
Page 16: ...Parts Policy Availability It is the policy of the manufacturer to maintain parts availability for the duration of production and a period of five years thereafter in accordance with industry standard...