9
ELECTRICAL INSTALLATION
IMPORTANT:
Switch off the electricity supply at
the mains before proceeding.
• The supply cable
MUST
be secured either by
routing through conduit, in trunking, or by
embedding in the wall, in accordance with
IEE regulations.
NOTE:
Conduit entry can only be from rear.
NOTE:
Deviations from the designated entry
points will invalidate product approvals. The
cable entry points are listed on
page 3
.
• Seal around rear entry cable to prevent water
ingress into the wall.
Installation
- ELECTRICAL INSTALLATION
6
check list
SECTION
Installation
- FIT TO THE WALL & CONNECT THE SHOWER SUPPLIES
FIT TO THE WALL & CONNECT THE
SHOWER SUPPLIES
Pipe/Electrical access points
• If bottom or right surface entry is required
for the mains cold water, then the necessary
opening will need to be cut out in the cover
and the trimplate
(fig.8)
.
• If surface cable entry from the top is required
then a small area will need to be cut out in
the backplate
(fig.9)
.
• If installing a feed pipe from the rear or
bottom, the centre of the inlet valve to the
wall surface is 21mm
(fig.7)
.
7
check list
SECTION
Fig.8
REAR OF
COVER
Trimplate
Remove for
right entry
Remove for
bottom entry
Remove for
right entry
Remove for
bottom entry