IVORY 4 electric shower
14
COMMISSIONING
•
Carefully guide the cover onto the backplate
making sure the wires are not trapped.
•
While applying slight pressure to the
front cover, secure in place using the
three retaining screws.
•
The first operation of the shower is intended
to flush out any remaining unit debris, and
to make sure the heater unit contains water
before the elements are switched on.
•
This operation must be carried out with
the flexible hose screwed to the outlet but
WITHOUT
the showerhead attached.
Make sure the outlet from the flexible hose is
directed to waste.
1.
Before switching on the electric and mains
water supplies to the shower, check that the
power selector is in the
OFF
position and
the temperature control is turned to the
MINIMUM
flow position
(fig.17)
.
Note: Failure to turn the control to
MINIMUM FLOW may cause the PRD to
operate.
2.
Turn on the electric and mains water supplies
to the shower.
3.
Turn the power selector to the
COLD
setting
(fig.18)
and wait until water starts to flow
from the flexible hose.
4.
Slowly turn the temperature control fully
anti-clockwise to the
MAXIMUM
flow
position
(fig.18)
.
It will take about thirty seconds for a smooth
flow of water to be obtained while air and
any debris is being flushed from the shower.
When there is a smooth flow of water turn
the temperature control steadily from
MAXIMUM
to
MINIMUM
and back again
several times to release any trapped air within
the unit.
5.
Once flushing out has been completed turn
the power selector to
OFF
.
6.
Fit the showerhead to the flexible hose and
place in the showerhead holder.
7.
The shower is now ready for normal operation.
Power selector
to
OFF
Temperature
control set at
MINIMUM
flow setting
Fig.17
Turn the
power
selector
to
COLD
Turn the
temperature
control to the
MAXIMUM
flow setting
Fig.18