20
NOTE:
Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
should be carried out by a suitably qualified person.
In the unlikely event of a fault occurring please contact Triton Customer Service.
DO NOT remove the shower from the installation.
FAULT FINDING/TROUBLESHOOTING
3
Water too cool
or cold -
continued
3.3
Reduction in ambient
water temperature.
3.3.1
Readjust flow rate to give reduced flow.
3.3.2
Select ‘high’ power.
3.4
Electrical malfunction.
3.4.1
Have unit checked by suitably qualified
electrician or contact Customer Service.
3.5
Safety cut-out
operated.
3.5.1
Thermal safety cut-out device has operated.
Have the unit checked by a suitably qualified
engineer or contact Customer Service.
4
Pressure relief
device has operated
(water ejected from
PRD tube).
4.1
Blocked showerhead.
4.1.1
Clean sprayplate and then fit a new PRD.
4.2
Twisted/blocked
flexible shower hose.
4.2.1
Check for free passage through hose. Replace
hose if necessary and then fit new PRD.
4.3
Showerhead not
removed while
commissioning.
4.3.1
Fit new PRD. Commission unit with
showerhead removed.
5
Low Pressure LED
FLASHING.
5.1
Low pressure
condition.
5.1.1
Insufficient water flow available.
1. Check filter is not blocked.
2. Check water supply to shower is adequate
FAULT FINDING
Important:
Switch off the electricity at the mains supply and remove the circuit fuse before
attempting any fault finding inside the unit.
Problem/Symptom Cause
Action/Cure
Problem/Symptom
Cause
Action/Cure