background image

Push button mixer shower

4

PLUMBING REQUIREMENTS

DO NOT 

choose a position where the mixer 

shower could become frozen.

DO NOT 

connect to any form of tap or fitting 

not recommended by the manufacturer.

DO NOT

 use jointing compounds on any pipe 

fittings for the installation.

DO NOT

 solder fittings near the mixer shower 

as heat can transfer along the pipework and 
damage the mixer shower.

DO NOT

 subject the mixer shower to a water 

temperature above 80°C during installation, use, 
maintenance or disinfection.

IMPORTANT:

 

•  The layout and sizing of pipework 

MUST

 

be such that nominally equal inlet supply 
pressures are achieved and the effects of 
other draw-offs are minimised.

•  The pipework should be installed such 

that other taps and appliances being 
operated elsewhere on the premises do not 
significantly affect the flow

•  When connecting pipework avoid using tight 

90° elbows; swept or formed bends will give 
the best performance.

•  The hot water pipe entry 

MUST

 be made to 

the left-hand side inlet, marked HOT, ‘H’ or 
with a red/orange label.

•  Suitable isolating valves (complying with 

Water Regulations and Bylaws) 

MUST

 be 

fitted on the hot and cold water supplies 
to the mixer shower as an independent 
means of isolating the water supplies should 
maintenance or servicing be necessary; 
position as close as is practicable to the water 
supply inlets of the mixer shower. If this 
isolator is fitted in a loft space, the loft must 
have a fixed access ladder and be boarded, 
with appropriate lighting from the access 
point to the isolator.

•  Flush pipework to clear the system of debris 

and check for leaks before connecting to the 
mixer.

Commercial Applications

For commercial applications in-line filters are 
recommended.

Hard Water Areas

a.  If it is intended to operate the shower 

in areas of hard water (above 200-ppm 
temporary hardness), a scale inhibitor may 
have to be fitted. For advice on the scale 
inhibitor, please contact the Triton Customer 
Experience team.

b.  For best performance the shower head 

MUST

 

be regularly cleaned to remove scale and 
debris.

WATER SYSTEM REQUIREMENTS

This mixer shower is suitable for:

•  Pumped gravity systems
•  Fully modulating type combination boilers
•  Multi-point hot water heaters
•  Thermal storage
•  Unvented systems
When installing this mixer shower with a 
combination or multi-point boiler, it may be 
necessary to install flow regulation. 
Check that the appliance is capable of delivering 
hot water at a minimum switch-on flow rate 
of 3 litres per minute. At flow rates between 3 
and 8 litres per minute, the appliance 

MUST

 be 

capable of raising the water temperature to 52°C 
minimum. 
Water temperature at the inlet of the mixer 
shower 

MUST

 remain relatively constant 

when flow rate adjustments are made - refer 
to the appliance operating manual to confirm 
compatibility with this mixer shower.
Where thermal store systems and instantaneous 
gas water heaters are used, if excessive draw-off 
takes place, the appliance may not be able to 
maintain an adequate output temperature.  
This could result in the shower temperature 
becoming noticeably cooler.
The hot supply temperature 

MUST

 remain a 

minimum of 10°C hotter than the required blend 
temperature for optimum performance.

Summary of Contents for 2181629F

Page 1: ...BOX ALTERNATIVELY REGISTER BY TEL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation...

Page 2: ...N COMPONENTS 1 DIMENSIONS 2 INTRODUCTION 3 PLUMBING WATER SYSTEM REQUIREMENTS 4 TYPICAL DOMESTIC INSTALLATIONS 5 6 PREPARING THE SHOWER 7 SITING OF THE SHOWER 7 INSTALLATION 8 12 LEAK TESTING 12 OPERA...

Page 3: ...ush button mixer shower 1 MAIN COMPONENTS A Mixer shower B Riser rail C Wall brackets D Riser rail wall bracket E Slider F Hose not shown G Shower head not shown H Fixed shower head not shown C A D B...

Page 4: ...mixer shower 2 780 1120mm 10 710mm 7 19mm 22mm 130x50mm 50 67mm 40mm 340mm 5 304mm 140mm 59mm 255x190mm DIMENSIONS All dimensions listed in this fitting book regarding the product and installation are...

Page 5: ...old supply temperature C Equal to or less than 25 This mixer shower is designed for high pressure systems found in the UK For effective operation of the internal seals the maximum static pressure must...

Page 6: ...he access point to the isolator Flush pipework to clear the system of debris and check for leaks before connecting to the mixer Commercial Applications For commercial applications in line filters are...

Page 7: ...pply pressures exceed 5 bar running An expansion vessel MAY be fitted and regularly maintained to prevent the shower mixer being damaged by excess pressures This may already be installed within the bo...

Page 8: ...reducing valve must be set at the same value as the unvented package pressure reducing valve Note An additional expansion vessel may be required if a second pressure reducing valve is installed This d...

Page 9: ...carefully covered to stop ingress of any debris while routing the supply pipework The mixer shower is suitable for exposed installation onto solid wall a stud partition wall dry lined wall or fixing t...

Page 10: ...uld pass through the support studs or noggins via a suitably sized hole fig 6 Decide upon the mounting position of the brackets on the wall and mark the centres Check the mounting marks are level and...

Page 11: ...the pipework is at rest against the depth of chasing the length of pipe protruding from the wall should be between 25mm MAXIMUM and 21mm MINIMUM from the face of the finished wall or tiles fig 11 Make...

Page 12: ...cover taking care not to damage the glass Offer the mixer shower to the brackets checking that the sealing washers are in place and carefully tighten the nuts Ensure the distance from the centre of th...

Page 13: ...and drill and plug the wall An appropriate drill bit should be used If the wall is brick plasterboard or a soft building block use appropriate wall plugs and screws should be used Secure the bracket t...

Page 14: ...Remedy any leaks found FITTING THE SHOWER HEAD Screw the conical end of the hose to the shower head then locate the shower head into the slider Screw the fixed head to the riser fixed head rail Make...

Page 15: ...RE CONTROL To adjust the water temperature rotate the temperature control to the desired temperature fig 21 To overcome the maximum temperature stop press the override button and turn DIVERTER CONTROL...

Page 16: ...ntee user safety Rotate the temperature control checking the minimum and maximum showering temperatatures ADJUST THE MAXIMUM TEMPERATURE STOP SETTING on page 14 if required The following is recommende...

Page 17: ...res The BuildCert TMV scheme recommends a maximum mixed water outlet temperatures of 41 C for showers The mixed water temperatures must never exceed 46 C The British Burns Association recommends 37 C...

Page 18: ...of routine maintenance of the internal of the mixer shower will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service test...

Page 19: ...7 8 0 11 5 14 0 16 5 18 0 Overhead showe head flow rate l m 2 6 3 6 4 0 5 0 5 6 8 0 12 0 15 0 17 0 18 5 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comp...

Page 20: ...water supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1...

Page 21: ...4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn off the mixer shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sur...

Page 22: ...Push button mixer shower 20...

Page 23: ...Push button mixer shower 21...

Page 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Reviews: