Bar mixer shower
13
Fig.18
DIVERTER CONTROL
The diverter has two position settings.
The first allows the overhead shower head to be
selected and the second position selects the hand
held shower head.
The positions are selected by rotating the handle
clockwise or anticlockwise
(fig.18)
.
LEAK TESTING
Fit the hose to the outlet and direct it to waste.
Open the isolating valves to the shower and
check for leaks. Remedy any leaks found.
COMMISSIONING
Start the water flow by rotating the flow control
(left hand side).
Make sure that the hot and cold water supplies
are fully open and at (or near to) their design
temperature and pressures, and are within the
requirements stated in the site requirements.
Make sure the temperature control (right hand
side) is at the maximum temperature setting.
Allow the shower to run at this maximum
temperature setting until the water temperature
has stabilised.
Rotate the temperature control until your desired
showering temperature is reached.
IMPORTANT
The temperature adjustment range must be
checked to guarantee user safety.
Rotate the temperature control checking
the minimum and maximum showering
temperatatures; ADJUST THE MAXIMUM
TEMPERATURE STOP SETTING if required.
The following is recommended for domestic
installations but must be carried out for
commercial installations. Perform a thermal shut
off test described within the maintenance section