In the event of a product fault or complaint occurring, 
the following procedure should be followed:
DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Experience on 

024 7637 2222

 having 

available your details including post code, the model number 
and power rating of the product, together with the date of 
purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Experience Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.co.uk. 

4.  Our engineer will require local parking and if a permit is required, 

this must be available to the engineer on arrival at the call.

5.  If loft access is required for isolation or to complete a repair, 

the loft must have a fi xed access ladder and be boarded, with 
appropriate lighting from the access point to and around the 
repair area.

6.  It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

7.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at the property when the 
service engineer calls or adequate parking/permit is not available.

8.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

9.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and 
will request payment prior to departing. If payment is not made 
on the day an administration charge will be added to the fi xed 
charge.

10.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

11.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning our Triton Customer Experience
team on 

024 7637 2222

. Payment should be made by

credit / debit card (excluding American Express or Diners Card).
Payment can also be made by pre-payment of a pro-forma
invoice, by cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON UK STANDARD GUARANTEE

This guarantee applies only to products installed within 
the United Kingdom and does not apply to products used 
expressly for commercial gain, unless this use has been
specifi ed by Triton.  This guarantee does not affect your 
statutory rights.
With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

5 years

 for use in a domestic environment from the date of 

purchase, provided that it has been installed by a competent 
person in full accordance with the fi tting instructions. 
All accessories such as shower heads, hoses and riser rails carry 

1 year

 parts only guarantee against manufacturing defects.

Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the instructions and has not 
been subject to misuse or damage or the effects of limescale 
build up. This product must not be taken apart, modifi ed or 
repaired except by a person authorised by Triton. 

What is not covered:

1.  Breakdown due to:  

 

a) 

use other than domestic use by the property 

occupants; 

b)

 wilful act or neglect; 

c) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 

controls; 

d) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 

accessories installed at the same time. Replacement of the 

Pressure Relief Device that only activates when the shower 

outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 

including the cost of repairing damage, breakdown, 

malfunction caused by corrosion, furring, frost or exposure 

to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves, or inaccessible proudct or 

valves located in a loft space without suitable access.

For the latest Terms & Conditions please see:

www.tritonshowers.co.uk/terms

PLEASE NOTE PRODUCT REGISTRATION IS ONLY

AVAILABLE TO UNITS PURCHASED & INSTALLED IN THE UK

UK SERVICE POLICY

Triton Showers
Triton Road
Nuneaton
Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Experience: 024 7637 2222

Trade Installer Hotline: 024 7637 8344

www.tritonshowers.co.uk

E-mail: [email protected]

E-mail: [email protected]

Triton reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2021

Summary of Contents for 2181403E

Page 1: ...quence of this instruction book IMPORTANT SAFETY ADVICE Failure to use genuine Triton parts may cause injury and invalidate your guarantee FOR YOUR SERVICE REFERENCE NOTE DOWN THE PRODUCT CODE BELOW F...

Page 2: ...ge MAIN COMPONENTS 1 DIMENSIONS 2 3 INTRODUCTION 4 5 TYPICAL DOMESTIC INSTALLATIONS 6 7 SITING OF THE SHOWER 8 PREPARING THE MIXER VALVE 8 INSTALLING THE BAR MIXER BRACKET 8 FITTING THE BAR MIXER 8 11...

Page 3: ...er shower 1 A B C D MAIN COMPONENTS E A Thermostatic mixer valve B Riser pipe C Push Fit Bracket D Wall Bracket E Fixed head pipe F Slider G Hose not shown H Handset not shown I Fixed shower head not...

Page 4: ...Bar mixer shower 2 DIMENSIONS 150 266 96 111 131 45...

Page 5: ...mixer shower 3 IMPORTANT All dimensions listed in this fitting book regarding the product and installation are approximate Consideration must be given for the adequate ceiling space 400 55 75mm 1127...

Page 6: ...ent to meet all normal requirements and will minimise the effects of scale in hard water areas Pressure Reducing Valve On sites where the running pressure is above 5 bar the use of a suitably sized pr...

Page 7: ...stem of debris and check for leaks before connecting to the mixer Commercial Applications For commercial applications in line filters are recommended Hard Water Areas a If it is intended to operate th...

Page 8: ...ly pressures exceed 5 bar running An expansion vessel MAY be fitted and regularly maintained to prevent the shower being damaged by excess pressures This may already be installed within the boiler che...

Page 9: ...cing valve must be set at the same value as the unvented package pressure reducing valve Note An additional expansion vessel may be required if a second pressure reducing valve is installed This does...

Page 10: ...ng to a laminate cubicle or panel SITING OF THE SHOWER AND ACCESSORIES Refer to fig 5 for correct siting of the shower The shower should be positioned as detailed with all controls within comfortable...

Page 11: ...face of the valve fig 7 Once the diverter has been fitted and faces forward fully tighten the small retaining grub screw located at the rear of the diverter assembly fig 8 FITTING THE MIXER SHOWER Off...

Page 12: ...ng sure the bracket engages the hexagonal fitting and the O ring is in place fig 11 Using a suitable screwdriver tighten the retaining screw to secure the rail into the support Screw the bottom part o...

Page 13: ...the bracket Tighten the diverter collar FITTING THE HOSE AND SHOWER HEAD Screw one end of the flexible hose to the bottom outlet connector on the diverter valve making sure that the sealing washer is...

Page 14: ...ixer rotate the on off flow control fig 16 TEMPERATURE CONTROL right hand side To adjust the water temperature rotate the temperature control clockwise for cool or anti clockwise for hot fig 17 To ove...

Page 15: ...their design temperature and pressures and are within the requirements stated in the site requirements Make sure the temperature control right hand side is at the maximum temperature setting Allow the...

Page 16: ...of 41 C for showers The mixed water temperatures must never exceed 46 C The British Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children WARNINGS Exposed meta...

Page 17: ...he valve will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service testing guidance has been given below which can be adj...

Page 18: ...17 0 19 5 22 0 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comply with EN1111 requirements Outlet temperature 38C Flow control fully open Open outlet No...

Page 19: ...2 5 Hot water supply blocked or restricted 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control k...

Page 20: ...y 4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure sto...

Page 21: ...Bar mixer shower 19...

Page 22: ...Bar mixer shower 20...

Page 23: ...Bar mixer shower 21...

Page 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...