XM1115-V1.0.0-NR
25
160-179
Internal program 4 (secne25~32 of EEPROM)
180-199
Internal program 5 (secne33~40 of EEPROM)
200-219
Internal program 6 (secne41~48 of EEPROM)
220-239
Internal program 7 (secne49~56 of EEPROM)
240-255
Music Control (secne of Program 1)
10. ERROR MESSAGE
When you turn on the fixture, it will make a reset at first. The display may show“Err channel is
XX” while there are problems with one or more channels. “XX” stands for channel 1, 2, 3, 4, 5,
6 who has the testing sensor for positioning. For example, when the display shows “Err channel is
Red LED -all arrays”, it means there is some error in channel 1. If there are some errors on
channel 5, channel 6 at the same time, you may see the error message, “Err channel is Pan
movement”, “Err channel is Tilt movement” ,flash repeated for 2 times, and then the fixture will
generate a second reset. If the fixture remain error message after performing reset more than 2
times, only the channels which have errors can not work properly, others can work as usual.
Please contact with dealer or manufacturer for service, self repair is not allowed.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is
defective (or its driving IC on the main PCB). The PAN-
movement is not located in the default
position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor
is defective (or its driving IC on the main PCB). The TILT-
movement is not located in the default
position after the reset.
11. CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and
must not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation
spots (ceiling, suspension, trussing).
3) Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
4) The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.
In order to make the lights in good condition and extend the life time, we suggest a regular
cleaning to the lights.