10
TRI105.INS.001.9
Veefil-PK TRI105-350-01 Installation manual
www.tritium.com.au
Veefil® is a registered trademark of Tritium Pty Ltd. © 2018 Tritium Pty Ltd
5. Remove tape and attach
cable glands
Remove the tape from the field wiring
input holes, and fit the supplied 4x M32
cable glands and 1x M25 cable gland.
6. Prepare wiring
Fit the individual power cabling into
each M32 cable gland, ensuring there is
enough length to add the M10 lugs (not
supplied) and attach to the busbars. Fit
each wire with an M10 lug.
7. Remove M10 fasteners
Each installation busbar is fitted with M10
fasteners. Remove these ready for wiring
in.
To continue to achieve the IP65 rating
the power cabling must be fitted
correctly into the cable gland.
Ensure the cable is sitting correctly in the
gland and tighten to ensure no water or
debris can enter. If in doubt, use an
appropriate outdoor rated sealant.
When the cable gland has been tightened,
pull on the cable to ensure it doesn’t slip.
Installation
Summary of Contents for Veefil TRI105-350-01
Page 2: ......