Tritech International Ltd
Super SeaSpy Camera OIM
Issue 0
TIL --- Eng --- Spec --- 098
Page
15 of 19
Focus
By rotating the nuts on each side of the camera module (shown in the picture in section INTERNAL LAYOUT
& CONFIGURATION) this will compress or release the module mounting collar and will affect the focus
accordingly.
Disassembly procedures
To access the internal part of the camera.
Unscrew the water block and disconnect it carefully.
Extract the nylon cord fitted between the front part of the housing and the camera body.(
Note
there are two
cords - the front one retains the port and should not normally be removed)
Gently pull off the body as straight as possible.
Before reassembly the operator
MUST
carefully inspect the O' ring and all sealing surfaces. If in any doubt
change the O' ring, clean it and lightly smeared with silicon grease.
Reassembly of the camera is done in reverse order. Make sure to check that the water block O' ring is in
position and correctly align the water block with the main 6-pin din connector before pushing it gently in
position.
To disassemble the water corrected port from the housing, unscrew the water block and remove it.
Extract the nylon cord maintaining the port in position.
Using a large nylon washer to protect the body inject air inside the body to a pressure of 1 bar max. The
acrylic port will be dislodged by this light pressure and removed easily. Take care not to over-pressure the
body so as to eject the port - and ensure that it is retained during this operation.
CAUTION!
Maintenance of water integrity is the responsibility of the user.
Internal damage caused by water ingress is not covered by product warranty unless
the cause can clearly be identified as a manufacturing defect.