Battery Selection

• LINE "OK" (Green Indicator Light) (all models except Power Center)

Indicates 120V AC power is present with no wiring faults detected. When this LED is illu-
minated,AC power is safe for connected equipment.

• LOW VOLTAGE  (Yellow Indicator Light) (all models except Power Center and
Command Console Compact)

Indicates that incoming line voltage has fallen below acceptable levels. If this LED illuminates
while you are using your Under-Monitor Surge Suppressor, you should turn off your equipment
to prevent possible low-voltage brownout damage. When the line voltage reaches a safe
level once again, this light will turn OFF, indicating brownout danger is over.

NOTE!

If the Line Fault indicator light illuminates, carefully check the AC receptacle the Under-
Monitor  Surge Suppressor is plugged into. The receptacle must be tight and securely
grounded. A loose AC receptacle may cause the Line Fault indicator light to illuminate.
It must be understood that this Red LED indicates the presence of a wiring fault, but
does not indicate the exact nature of the fault. Therefore, a qualified electrician should
be contacted to make necessary repairs.

NOTE!

If, after inspection by a qualified electrician, a wiring fault is not detected, the Line Fault
indicator light may be indicating that the surge-suppression components have been
compromised as a result of surge damage. Even if the surge suppressor is providing AC
power at all of the receptacles, it may not provide its total rated surge suppression as
outlined in the "Specifications" section. Should you require service, call Tripp Lite
Customer Support at (773) 869-1234. Explain fully the perceived problem to the cus-
tomer support person. They will either remedy the problem over the phone or give you
instructions about return, repair or exchange.

Summary of Contents for TouchMaster (MT-6

Page 1: ... power for your computer and various peripherals as well as advanced diagnostic indicators that display power protection status PLUS models include a set of RJ style phone jacks for protection against spikes surges and line noise on a single telephone line TouchMaster and Command Console models except Command Console Compact include premium ISOBAR surge suppression POSITIONING YOUR UNDER MONITOR S...

Page 2: ... in line from the telephone jack PLUS models MUST always be plugged into a 3 wire grounded outlet for the telephone protection to work Connect the phone cord from the wall jack directly to the PLUS jack labelled IN or LINE Connect the phone cord from the device to be protected directly to the PLUS jack labelled OUT or EQUIP The connected equipment is now protected against spikes surges and line no...

Page 3: ...led by the MASTER switch The indicator lights or the switches themselves depending on the model will illuminate when the switches are pushed ON and power is reaching the respectively labelled out lets on the rear of the unit The MASTER switch must be pushed ON for the other indi vidual switches to work Before turning the switches ON confirm that incoming AC power is safe for connected equipment ac...

Page 4: ...on components are intact and providing full protection against spikes and surges This LED should be illuminated anytime the MASTER switch is turned ON and power is present as indicated by one of the following T To ou uc ch hM Ma as st te er r T To ou uc ch hM Ma as st te er r P PL LU US S Green Indicator Light above the MASTER switch is illuminated C Co om mm ma an nd d C Co on ns so ol le e C Co ...

Page 5: ... Switches 1 Individual 2 Master Indicator Lights 3 Protection Present 4 Line Fault 5 Line OK 6 Low Voltage TouchMaster TouchMaster PLUS 1 2 3 6 4 5 Command Console Command Console PLUS 3 2 4 5 1 Command Console Compact 3 2 1 Command Console Compact ...

Page 6: ...d into The receptacle must be tight and securely grounded A loose AC receptacle may cause the Line Fault indicator light to illuminate It must be understood that this Red LED indicates the presence of a wiring fault but does not indicate the exact nature of the fault Therefore a qualified electrician should be contacted to make necessary repairs NOTE If after inspection by a qualified electrician ...

Page 7: ... COMPACT 4 8 1 1 900 72 000 0 ns 2 x 101 2 x 141 2 5 000 CCC 4 POWER CENTER PC 5 5 6 1 5 65 6 500 1 ns 21 8 x 121 8 x 13 PC 5 ALL MODELS Rated Input Voltage 120V AC 50 or 60 Hz Rated Current and Load Handling 15 amps maximum 1800 watts 15 amps maximum per receptacle Circuit Breaker 15 amp resettable Exceeds IEEE 587 category A B specifications All line cords are 3 conductor grounded High voltage s...

Page 8: ...E will repair or replace at TRIPP LITE S option equipment up to the specified value See ULTIMATE Insurance Policy Limits No coverage is allowed for damage entering from telephone or data lines unless they are separately protected as described below TELEPHONE AND DATA LINE TRANSIENTS Tripp Lite will repair or replace directly connected equipment that is damaged by transients on telephone and or dat...

Reviews: