background image

About This Guide

This document is part of the product.

 

Do not install or use the device until you have read and understood 

this document.

 

Keep this document for reference throughout the service life of the 

device. Pass this document on to any new owner or user.

For the most up-to-date version of this document, go to  

www.kathrein-ds.com

.

Storage and Transport

 

Transport and store the device in its original packaging.

 

Make sure there is no water condensation build-up.

Scope of Delivery

 

KAZ 10

 

Pre-assembled equipotential bonding wire

 

Mounting screws and rawlplugs

 

Instructions for use

Features

 

Protection of system components in DVB-S/C/T reception and distri-

bution systems

 

Deployment of KAZ 10 increases the surge discharge capability of 

KAZ 11 and KAZ 12

 

Fulfils categories C2/C3/B2/D1 according to EN 61643-21

 

Remote feeding for DC voltages from 0...+20 V / max. 0.4 A

 

Passage for 22 kHz and DiSEqC™ signals

 

Impedance: 75 Ω

 

For indoor installation only

 

  

KAZ 10

2180000001

Surge Protection Device, 5-way

Installation and Safety Instructions

Danger to life from electric shock and fire hazard due 

to electric current!

 

Connection and installation of the device may only be 

carried out by a qualified electrician. National regula-

tions and safety regulations must be complied with 

(see also EN 60728-11).

 

Before installation, the equipment must be checked 

for external damage. Should there be damage or 

another defect, the equipment must not be installed.

 

The use of the device is permissible only under the 

conditions listed and shown in these installation  

instructions. In case of loads which exceed the indi-

cated values, the equipment and any electrical equip-

ment connected to it can be destroyed.

 

Make sure that the maximum operating voltage of 

the system does not exceed the highest continuous 

voltage U

DC

 and the maximum remote supply current 

I

DC

.

 

The device is designed for a clean and dry environ-

ment. Do not expose the device to any mechanical 

and/or thermal stress that exceeds the limits of the 

specified technical data.

 

The device must be installed so that it is inaccessible 

to children.

 

The equipment must be provided with an equipoten-

tial bonding wire (Cu, at least 4 mm

2

).

To increase the protective effect, it is recommended to 

use KAZ 11 as a fine protection directly before the device 

to be protected as well as KAZ 12 as a coarse protection at 

the house entry point (see Fig. 4).

Intended Use

 

This device is intended solely for installation in DVB-S/C/T reception 

and distribution systems. It may only be installed by trained specia-

lists.

 

Any use other than that specified or failure to observe these applica-

tion notes will invalidate the warranty or guarantee.

 

The manufacturer accepts no liability for accidents caused by the 

user opening the unit.

 

Opening the unit and attempting to repair it yourself voids all 

warranty claims.

Other Measures

 

With remotely-fed antenna amplifiers, no additional protective circuit 

is necessary. With mains-fed devices, an additional protective device 

for the mains feed is required (e.g. S-Protector, NSM-Protector or 

DEHNsafe). The PE connection of the mains feed must be connected 

with the grounding connection of the KAZ 10 surge protector at low 

resistance.

 

If cable systems require the use of a gas discharge arrester at the 

building transfer point (BTP), a decoupling distance of at least 1 m 

between the BTP and the KAZ 10 is required to ensure coordina-

tion of the two protective measures. The use of an upstream gas 

discharge arrester (e.g. KAZ 12) increases the surge current capabi-

lity of the KAZ 10 surge protector.

 

Equipotential bonding is performed according to Fig. 3. Additio-

nally, the ground terminals must be connected with short cables 

(Cu, 4 mm

2

).

Connecting the KAZ 10

1.  Connect the OUT side of the KAZ 10 to the inputs of the devices to 

be protected (multi-switch, amplifier, ...). Use short coaxial cables 

with F connectors. Make sure that each system component is 

always connected to the equipotential bonding and, if necessary, 

insert additional grounding blocks (e.g. EMU 21).

2.  The lateral mounting brackets (see 1 Fig. 1) allow you to mount the 

surge protector on a flat surface.

3.  Connect the cables coming from the satellite antenna (see 2 Fig. 1), 

and any existing terrestrial antennas to the IN side of the surge 

protector.

4.  Connect the housing via the lateral earthing screw (see 3 Fig. 1) to 

the local equipotential bonding by the shortest possible route.

IN

OUT

KAZ 10

K-019

218000001

protected

1

2

3

47 - 2400 MHz

DE - 83022 Rosenheim

Fig. 1:  Connecting the KAZ 10

Reviews: