Important Safety Instructions

SAVE THESE  INSTRUCTIONS!

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
UPS Systems.

Location Warnings

• Install your UPS System (whether for a mobile or stationary application) in a location or compartment that minimizes exposure to 

heat, dust, direct sunlight and moisture.

• Although your UPS System is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit 

and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might 
accumulate. Mounting should be in the driest location available.

• Leave a minimum of 2" clearance at front and back of the UPS System for proper ventilation. To avoid automatic UPS System 

shutdown due to overtemperature, any compartment that contains the UPS System must be properly ventilated with adequate 
outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.

• Do not install near flammable materials, fuel or chemicals.

Battery Connection Warnings

• The UPS System will not operate (with or without utility power) until batteries are connected.

• Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type. 

• Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be 

installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some 
ventilation to outside air. 

• Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.

• Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury 

or property damage could result.

Equipment Connection Warnings

Do not use a Tripp Lite UPS System in life support or healthcare applications where a malfunction or failure of a Tripp Lite
UPS System could cause failure of, or significantly alter the performance of, a life support device or medical equipment.

• Corded models: Do not modify the UPS System’s plug or receptacle in a way that eliminates its ground connection. Do not use 

power adapters that will eliminate the plug’s ground connection.

• Connect your UPS System only to a properly grounded AC power outlet or hardwired source. Do not plug the unit into itself; this 

will damage the device and void your warranty.

• You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of 

the UPS System.

Operation Warnings

• Your UPS System does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.

• Potentially lethal voltages exist within the UPS System as long as the battery supply and/or AC input are connected. During any 

service work, the battery supply and AC input connection (if any) should therefore be disconnected.

• Do not connect or disconnect batteries while the UPS System is operating in either inverting or charging mode. Dangerous arcing may

result. Operating Mode Switch should be in the OFF position. 

Summary of Contents for TMU Series

Page 1: ...abinets Premium Protection for Critical Equipment Built in ISOBAR power conditioning spike surge low voltage high voltage and lightning protection Rapid recharge high amp 3 stage battery charger Rapid automatic transfer switching from line power to inverter power Automatic overload protection Relay for low battery alarm flashing red mode traffic signals Cost Effective Features for All Budgets Powe...

Page 2: ...ranty to register the warranty of your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details Service Maintenance Service Before returning your UPS System for service follow these steps 1 Review the installation and operation instructions to ensur...

Page 3: ...application in a dead air compartment Ideally any compartment would have some ventilation to outside air Sparks may result during final battery connection Always observe proper polarity as batteries are connected Do not allow objects to contact the two DC input terminals Do not short or bridge these terminals together Serious personal injury or property damage could result Equipment Connection War...

Page 4: ... prolongs equipment service life Hardwire AC Input Output Cover Plate Battery Temperature Sensing Connector not on TMU612 models prolongs battery life by adjusting charge based on bat tery temperature Use with included cable See Configuration section for details Low Battery Relay not on TMU612 models when battery reaches low voltage this relay can signal traffic controller to go to flashing red mo...

Page 5: ...upport The light will BLINK to alert you when the inverter shuts down due to a severe overload or over heating If this happens turn the operating mode switch OFF remove the overload and let the unit cool You may then turn the operating mode switch to AUTO REMOTE after it has adequate ly cooled This light will be off when AC power is supplying the load BATT VOLT CHRG CURR LEDs If the switch is in t...

Page 6: ...el of your unit see dia gram as follows A1 A2 Most of your connected equipment will perform adequately when your UPS System s High AC Input Voltage Point DIP Switch 2 of Group A is set to 135V and its Low AC Voltage Input Point DIP Switches 3 and 4 of Group A or DIP Switch 3 for 612 models are set to 95V However if the unit frequently switches to battery power due to momentary high low line voltag...

Page 7: ... any load size Configuration continued B1 B2 B3 B4 B1 B2 B3 B4 B1 B2 B3 B4 B1 B2 B3 B4 B1 B2 B3 B4 Connect Battery Temperature Sensing Cable 1012 and 2012 models only The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature Connect the sensor cable the cable included with select models has an RJ style connector on one e...

Page 8: ...equate ventilation space behind the cooling fan s they should not be removed 5 87 in 14 91 cm 1 64 in 4 15 cm 5 87 in 14 91 cm 5 57 in 14 16 cm 5 57 in 14 16 cm 9 59 in 24 35 cm 9 59 in 24 35 cm 6 75 in 17 1 cm 7 87 in 20 cm 6 75 in 17 1 cm 4 5 in 11 4 cm A C B M A B M A B C A B Note Cabinets may have different front panel features but all mount as per the figure above or via the Lateral Mounting ...

Page 9: ...ow traffic managers to feel comfortable with fewer battery amp hours and shorter back up times thereby minimizing budgetary outlays for batteries auxilliary cabinets and battery maintenance STEP 1 Determine Total Wattage Required Add the wattage ratings of all equipment you will connect to your UPS System Wattage ratings are usually listed in equipment manuals or on nameplates If your equipment is...

Page 10: ...fuse s and fuse block s within 18 inches of the battery The fuse s rating must equal or exceed the Minimum DC Fuse Rating listed in your UPS System s specifications See Specifications for fuse and fuse block rec ommendations See diagrams below for proper fuse placement Battery Connection Connect your UPS System to your batteries using the following procedures WARNING Failure to properly ground you...

Page 11: ...e UPS System s AC input cord into an outlet providing 120V AC 60Hz power Make sure that the circuit you connect your UPS System to has adequate overload protection such as a circuit breaker or a fuse Plug your equipment into the UPS System s AC receptacles Any equipment you connect to it will benefit from your UPS System s built in ISOBAR power conditioning including surge spike and lightning prot...

Page 12: ...ltage Check external are slowly flashing second flashes with prevent battery damage battery connections and fuse Unit automatically resets when Operating Mode Switch in the condition is cleared AUTO REMOTE position All Three BATT VOLT CHRG CURR LEDs Battery is overcharged Unit will shut down to prevent battery Disconnect any auxiliary chargers Reset by moving Operating Mode are rapidly flashing se...

Reviews: