Locating a Short or Breakage in a Non-Powered Cable

RJ45 Wire Mapping 

Notes:

•  Set the volume from 6-8 when locating a short or breakage.
•  Locating a short or breakage can only be performed on a non-powered cable.
•  The included headphones can be used when in a noisy environment to ensure you are hearing 

the tone from the Remote Probe Unit.

•  Flip the light switch on the side of the Remote Probe Unit to turn on the light for use in dark 

areas.

1.  Flip the switch on the Main Tester to the 

Scan

 position. The 

Status

 LED will flash to 

indicate the Main Tester is ready for operation.

2.  Connect the included alligator clip adapter to the corresponding port on the Main 

Tester.
• When locating a 

short

, connect both alligator clips to the bare wires on the cable 

being tested.

• When locating a 

breakage

, connect the red alligator clip to one of the bare wires, 

leaving the black alligator clip free.

3.  Flip the switch on the Remote Probe Unit to the 

Scan

 position. The 

Power

 LED will 

illuminate to indicate the Remote Probe Unit is ready for operation.

4.  Run the probe of the Remote Probe Unit along the cable. The tone will sound, 

indicating that the area where the probe is currently located is undamaged. Continue 
running the probe along the cable until the tone stops, which will be the location of 

the short or breakage.

1.  Flip the switch on the Main Tester to the 

Test

 position. The 

Verify

 LED will flash to 

indicate the Main Tester is ready for operation.

2.  Flip the switch on the Remote Probe Unit to the 

Scan

 position. The 

Power

 LED will 

illuminate to indicate the Remote Probe Unit is ready for operation.

3.  Connect RJ45 cable from the RJ45 port of the Main Tester to the RJ45 port of the 

Remote Probe Unit.

4.  The Pin LEDs on the Main Tester and Remote Probe Unit will illuminate per below.

 

Note: 

When performing a Wire Mapping operation, pressing the

 SET

 button will change the 

speed at which the LEDs flash.

• 

Good Cable

 – When a UTP cable is properly wired, the LEDs on both units will 

flash in sequence from 1 through 8. For a good STP cable, the LEDs will flash in 

sequence from 1 through 8, including G.

 Short

 – In the case of a short, the LED(s) of the pin(s) in which a short is present 

will not illuminate on the Remote Probe Unit. The LEDs on the Main Tester unit will 
all continue to illuminate.

• 

Open

 – In the case of an open pin, the LED(s) of the open pin(s) will remain off on 

both the Main Tester and Remote Probe Unit.