background image

Owner’s Manual

1111 W. 35th Street • Chicago, IL 60609 USA

(773) 869-1234 • www.tripplite.com

Copyright ©2007 Tripp Lite. All rights reserved. 

SmartOnline™ is a trademark of Tripp Lite.

Internal Battery Packs

For use with Tripp Lite SmartOnline

3-Phase 

UPS Systems that accept internal battery pack connection.

Model #: SURBC2030

W

arranty

Registration:

register online toda

y f

or a c

hance 

to win a FREE 

Tripp Lite pr

oduct—

www

.tripplite

.com/warranty

Important Safety Warnings

Adding or Replacing Internal Batteries

Warranty & Warranty Registration

1

2

5

Español

6

Français

11

Important Safety Warnings

SAVE THESE INSTRUCTIONS! This owner's manual contains important instructions and warnings that must be followed during the installation and
operation of SURBC2030 Internal Battery Packs. The owner's manuals included with compatible products (UPS systems and battery module
compartments) include additional safety instructions that must be followed during installation and operation. Failure to heed these instructions may
cause permanent damage to the UPS system (voiding its warranty) and create a potential for serious personal injury or death from lethal high voltage.

• Do not use Tripp Lite UPS Systems or Internal Battery Packs in life support applications in which a malfunction or failure of a Tripp Lite UPS 

System or Internal Battery Pack could cause failure or significantly alter the performance of a life support device.

• The UPS system contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply.

• Your UPS does not require routine maintenance. Do not open the UPS's power module for any reason; there are no user-serviceable parts inside. 

Because of the risk of electrical shock, only qualified electricians should open the battery module.

• Because the batteries present a risk of electrical shock and burn from high short-circuit current, batteries should be changed only by trained service 

personnel observing proper precautions. Remove watches, rings, and other metal objects. Use tools with insulated handles. Wear rubber gloves and 
boots. Do not lay tools or metal parts on top of the batteries. Do not short or bridge the battery terminals with any object.

• Do not dispose of the batteries in a fire. The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the USA only, refer to 

these sources for recycling information: 1-800-SAV-LEAD (1-800-728-5323), 1-800-8-BATTERY (1-800-8-228-8379), or www.rbrc.com.

• Internal batteries must be replaced by equivalent batteries available from Tripp Lite.

• Do not operate your UPS without batteries.

• Battery fuses should be replaced only by factory authorized personnel. Blown fuses should be replaced only with fuses of the same number and type.

• Potentially lethal voltages exist within this unit as long as the battery supply is connected. Service and repair should be done only by trained 

personnel. During any service work, the UPS should be turned off or put into manual bypass.

• Do not connect or disconnect the battery modules while the UPS is operating from the battery supply or when the unit is not in bypass mode.

1

Summary of Contents for SURBC2030

Page 1: ...ery The output terminals may be live even when the UPS is not connected to an AC supply Your UPS does not require routine maintenance Do not open the UPS s power module for any reason there are no use...

Page 2: ...e string with a BLACK cable and one string with a RED cable The batteries are designed for hot swap replacement which allows connected equipment to continually receive AC mains power but not battery b...

Page 3: ...ch fuse block Save the fuses 4 Disconnect the BLUE and WHITE jumper cables attached to each fuse block 5 CAUTION When disconnecting the jumper cables pull them straight away from the fuse block with e...

Page 4: ...VDC rated cartridge fuses Use a voltmeter user supplied to test the voltage of the battery pack Observe proper polarity connect the voltmeter s BLACK probe to the battery pack s BLACK connector connec...

Page 5: ...Y SET FORTH HEREIN EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ALL IMPLIED WARRANTIES INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FO...

Page 6: ...equiere de mantenimiento de rutina No abra el modulo de potencia del UPS por ning n motivo no hay partes en el interior a las que el usuario les necesite dar mantenimiento Debido al riesgo de una desc...

Page 7: ...ar las bater as El m dlo de bater as puede aceptar hasta cuatro m dulos de bater as Cada m dulo se compone de dos cadenas El diagrama muestra a los cuatro m dulos de bater as conectadas para efectos d...

Page 8: ...de lado a lado ya que esto puede da ar al conector Dependiendo de su preferencia coloque el sistema UPS en modo de Derivaci n o ap guelo completamente Vea Operaci n del Interruptor de Derivaci n Manua...

Page 9: ...DE LOS FUSIBLES Los fusibles protegen contra da os por corto circuitos Si se presentara una fuerte sobrecarga o corto circuito el fusible se quemar Un m dulo de bater as con un fusible quemado no ent...

Page 10: ...identificaci n del producto junto con los s mbolos de aprobaci n e informaci n requeridos Al solicitar informaci n sobre el cumplimiento de las normas para este producto siempre mencione el n mero de...

Page 11: ...tion de l onduleur sous aucun pr texte aucune pi ce interne n est r parable par l utilisateur cause du risque de choc lectrique seuls des lectriciens qualifi s devraient ouvrir le module de la batteri...

Page 12: ...tterie peut accepter jusqu quatre blocs de batterie chaque bloc consistant en deux cha nes Le sch ma montre les quatre blocs de batterie connect s uniquement des fins illustratives Le nombre r el de b...

Page 13: ...bles Conserver les fusibles 4 D connecter les c bles de pontage BLEU et BLANC attach chaque bloc fusibles 5 ATTENTION Lorsque vous d connectez le c ble de pontage les retirer du bloc fusibles avec une...

Page 14: ...Utiliser un voltm tre fourni par l utilisateur pour tester la tension du bloc de batterie Observer la bonne polarit Connecter la sonde NOIRE du voltm tre au connecteur NOIR du bloc de batterie et son...

Page 15: ...ervice tripplite com CETTE GARANTIE NE S APPLIQUE PAS L USURE NORMALE OU AUX D GATS DUS UN ACCIDENT UNE MAUVAISE UTILISATION UN ABUS OU UNE N GLIGENCE LE VENDEUR N ACCORDE AUCUNE GARANTIE EXPRESSE AUT...

Page 16: ...16 200702236 93 2659 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 www tripplite com...

Reviews: