Basic Operation

OFF

ON

Switches

With your UPS plugged in, set this switch according to the
recommendations in Step 3 of the Quick Installation section.
 

"ON" Position

Function:

 

ENABLES battery backup.

 

UPS Conditions:

 The UPS

battery is charging. Power is ON at the UPS receptacles. The "    "
indicator light is illuminated. 

Setting Advantages:

 Provides

battery backup during blackouts or brownouts.

"OFF" Position

Function:

 

DISABLES battery backup. 

UPS Conditions:

 The UPS

battery is charging. Power is ON at the UPS receptacles. The "   "
indicator light is illuminated. The "    " indicator light is flashing.

Setting Advantages:

 Continues to charge the battery when

power is present while turning OFF the inverter to prevent battery
backup operation when equipment is not in use.

Use this momentary switch to do three things:

Silence the UPS alarm*

Move this switch to the left and release it. Note: When the battery
is nearly depleted the alarm resumes (and cannot be silenced) to
alert you to immediately shut down connected equipment.

*The UPS alarm consists of a series of short beeps followed by a brief pause. The alarm is activated when
the UPS switches to battery during a blackout or brownout.

Test your UPS's battery charge**

With your connected equipment and your UPS turned ON, move
this switch to the left; hold it there for 2 seconds and release it. The
UPS will beep and flash its LEDs as it momentarily switches to
battery to test its charge. If the UPS alarm sounds afterwards, or
the properly-sized load is not supported, let your UPS charge its
batteries for 12 hours and repeat the test. If alarm still sounds,
contact Tripp Lite for service. CAUTION: Do not unplug your UPS to
test its batteries. This will remove safe electrical grounding and
may introduce a damaging surge into your network connections.

**If your model is not equipped with this switch, you can still test your UPS batteries. First plug your UPS
into a grounded surge suppressor (which will maintain the ground connection), then turn the surge
suppressor's power switch OFF.

Cold-Start your UPS

If your UPS is equipped with a MUTE/TEST switch, you may “cold
start” it and use it as a stand-alone power source when utility
power is not present, providing that the UPS's battery is charged.
To “cold start” your UPS, first turn the "OFF/ON" switch ON.
Then, move the MUTE/TEST switch to the left, hold momentarily
and release when the "

" indicator light begins to flash.

–Optional Installation–

(continued)*
OPTION 3 (Brownout Voltage Adjustment)
Adjust the Voltage Potentiometer (UPS back panel)
clockwise to lower the voltage point at which the
UPS switches from on-line to battery output.**

* Your UPS will function properly without these connections
or settings. **  Use caution when adjusting the potentiometer
while the UPS is powering a voltage-sensitive load.

NORM

Available

on select

models

200008280 Internet I 230V Owner's Manual.p65

8/25/00, 2:35 PM

4

Summary of Contents for Standby UPS Systems Internet I

Page 1: ...t Chicago IL 60609 USA CustomerSupport 1 773 869 1234 www tripplite com Owner sManual INTERNET I Standby UPS Systems 230V ESPAÑOL p 7 FRANÇAIS p 13 Quick Installation p 3 4 Basic Operation p 4 5 Storage Service p 6 Specifications p 6 Safety p 2 Warranty Insurance p 6 ...

Page 2: ...r life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS ...

Page 3: ...r UPS s female output receptacles A B Set your UPS s OFF ON Switch USA Canada WesternEurope Set it and leave it ON at all times AllOtherCountries Setto OFF whenyouarenotusingconnectedequipment WARNING When set to OFF UPS will not provide battery backup during a blackout or brownout Setto ON whenyouareusingconnectedequipment See Basic Operation section for the Switch Function UPS Conditions and Set...

Page 4: ...ds and release it The UPS will beep and flash its LEDs as it momentarily switches to battery to test its charge If the UPS alarm sounds afterwards or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm still sounds contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical gro...

Page 5: ...perly without this connection Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power This red light will turn ON when your UPS is providing your equipment with battery power This yellow light will turn ON after you test your UPS battery s charge...

Page 6: ...st turn your UPS OFF and disconnect its power cord from the wall outlet Then disconnect all equipment to avoid battery drain If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of ...

Reviews: