Tripp Lite Standby UPS Systems Internet I Owner'S Manual Download Page 2

2

This manual contains important instructions and warnings that should be
followed during the installation, operation and storage of all Tripp Lite UPS
Systems.

UPS Location Warnings

• Install your UPS indoors, away from excess moisture, heat, dust

and direct sunlight.

• For best performance, keep the indoor temperature between 0° C and

40° C (between 32° F and 104° F).

• Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

• Connect your UPS to a grounded AC power outlet. Do not remove or

modify the ground pin of the UPS's plug. Do not use plug adapters that
would circumvent the UPS's ground connection.

• Do not plug your UPS into itself; this will damage the UPS and void

your warranty.

• If you are connecting your UPS to a motor-powered AC generator,

the generator must provide clean, filtered computer-grade output.

Equipment Connection Warnings

• Do not use Tripp Lite UPS Systems for life support applications in

which a malfunction or failure of a Tripp Lite UPS System could cause
failure or significantly alter the performance of a life-support device.

• Do not connect surge suppressors to the output of your UPS. This may

damage your UPS and will void both the surge suppressor and UPS
warranties.

Battery Warnings

• Your UPS does not require routine maintenance. Do not open your

UPS for any reason. There are no user-serviceable parts inside.

• Battery replacement must be performed by qualified service personnel.

Because the batteries present a risk of electrical shock and burn from
high short-circuit current, observe proper precautions. Unplug and
turn off the UPS before performing battery replacement. Use tools
with insulated handles and replace the existing batteries with the
same number and type of new batteries (Sealed Lead-Acid). Do not
open the batteries. Do not short or bridge the battery terminals with
any object.

• The UPS batteries are recyclable. Refer to local codes for disposal

requirements. Do not dispose of the batteries in a fire.

• Do not attempt to add external batteries.

Safety

200008280 Internet I 230V Owner's Manual.p65

8/25/00, 2:34 PM

2

Summary of Contents for Standby UPS Systems Internet I

Page 1: ...t Chicago IL 60609 USA CustomerSupport 1 773 869 1234 www tripplite com Owner sManual INTERNET I Standby UPS Systems 230V ESPAÑOL p 7 FRANÇAIS p 13 Quick Installation p 3 4 Basic Operation p 4 5 Storage Service p 6 Specifications p 6 Safety p 2 Warranty Insurance p 6 ...

Page 2: ...r life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS ...

Page 3: ...r UPS s female output receptacles A B Set your UPS s OFF ON Switch USA Canada WesternEurope Set it and leave it ON at all times AllOtherCountries Setto OFF whenyouarenotusingconnectedequipment WARNING When set to OFF UPS will not provide battery backup during a blackout or brownout Setto ON whenyouareusingconnectedequipment See Basic Operation section for the Switch Function UPS Conditions and Set...

Page 4: ...ds and release it The UPS will beep and flash its LEDs as it momentarily switches to battery to test its charge If the UPS alarm sounds afterwards or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm still sounds contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical gro...

Page 5: ...perly without this connection Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power This red light will turn ON when your UPS is providing your equipment with battery power This yellow light will turn ON after you test your UPS battery s charge...

Page 6: ...st turn your UPS OFF and disconnect its power cord from the wall outlet Then disconnect all equipment to avoid battery drain If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of ...

Reviews: