background image

connected devices

Supports Tripp Lite's WatchDog software application (requires optional WATCHDOGSW)

Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter

Emergency Power Off (EPO) interface with cable

Multi-function audible alarms and set of 5 front panel LEDs

Network-grade AC surge suppression

Attractive gray color scheme

Specifications

OUTPUT

Output Volt Amp Capacity
(VA)

2200

Output kVA capacity (kVA)

2.2

Output Watt Capacity
(watts)

1600

Output kW capacity

1.6

Output power factor

0.7

Nominal Output Voltage(s)
Supported

220V; 230V; 240V

Nominal Voltage details

230v inverter nominal output voltage

Frequency compatibility

50 / 60 Hz

Output voltage regulation
(line mode)

-19% +8%

Output voltage regulation
(Battery mode)

+/- 5%

Built-in UPS output
receptacles

8 C13 outlet(s); 1 C19 outlet(s)

Included output power
cables

Includes 3 C13 to C14 output power cables

Built-in controllable
switched load banks

Three switchable two-outlet C13 load banks

Output circuit breaker

10A (x2) - each breaker protects 4 C13 outlets each, C19 is unbreakered

Output AC waveform (AC
mode)

Sine wave

Output AC waveform
(battery mode)

PWM sine wave

INPUT

Rated input current (at
maximum load)

11.3A

Nominal Input Voltage(s)
Supported

230V AC

UPS input connection type

C20 inlet

UPS input connection
description

IEC320-C20 input connection accepts a variety of detachable cordsets to match country or site-specific wall
receptacles

Phase

Single-Phase

Summary of Contents for SmartPro SMARTINT2200VS

Page 1: ...offers option for instantaneous power off of UPS and connected equipment in the case of fire or emergency Multi function audible alarms and set of 5 front panel LEDs offer at a glance notification of UPS and line power status Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges and line noise Attractive gray color scheme Package...

Page 2: ...ltage Frequency compatibility 50 60 Hz Output voltage regulation line mode 19 8 Output voltage regulation Battery mode 5 Built in UPS output receptacles 8 C13 outlet s 1 C19 outlet s Included output power cables Includes 3 C13 to C14 output power cables Built in controllable switched load banks Three switchable two outlet C13 load banks Output circuit breaker 10A x2 each breaker protects 4 C13 out...

Page 3: ...tween 151 and 176 are boosted by 30 LEDS ALARMS SWITCHES LED Indicators 5 LEDs indicate line power battery power overload voltage regulation and battery low replace status Alarms Audible alarm indicates power failure overload and low battery conditions Alarm cancel operation Power fail alarm can be silenced using alarm cancel switch once silenced alarm will re sound to indicate low battery status ...

Page 4: ...le Noise Audible Noise 47dBA At Front Side 1 Meter COMMUNICATIONS Communications interface USB DB9 Serial Contact closure Network monitoring port description Supports detailed monitoring of UPS and site power conditions 2 USB ports 1 DB9 serial and 1 DB9 contact closure port 4 total PowerAlert software Included Communications cable 2 USB and 2 DB9 cables included WatchDog compatibility Supports Wa...

Page 5: ...tors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU 1 PDU12IEC Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment 1 P004 006 6 ft 18AWG Power cord IEC 320 C14 to IEC 320 C13 1 SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 U022 010 10 ft USB2 0 A B Gold Device Cable A Male to B Male 1 WA...

Reviews: