Operating Temperature
Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature
Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr. (full
load)

105.2

Battery mode BTU / hr.
(full load)

463.6

COMMUNICATIONS

Communications interface

USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network monitoring port
description

Supports detailed monitoring of UPS and site power conditions

PowerAlert software

Included

Communications cable

USB and DB9 cabling included

WatchDog compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER

Transfer time

2-4 milliseconds

Low voltage transfer to
battery power (setpoint)

151

High voltage transfer to
battery power (setpoint)

282

SPECIAL FEATURES

Grounding lug

Back panel grounding lug

Cold Start (startup in
battery mode during a
power failure)

Cold-start operation supported

High availability UPS
features

Hot swappable batteries

Green & high efficiency
features

Greater than 95% efficiency - GREEN UPS; Individually controllable load banks

CERTIFICATIONS

UPS Certifications

CE; Tested to GOST (Russia); Tested to SASO (Saudi Arabia); Tested to IRAM (Argentina)

WARRANTY

Product Warranty Period
(International)

2-year limited warranty

Product Warranty Period
(Mexico)

2-year limited warranty

Product Warranty Period
(Puerto Rico)

2-year limited warranty

Related Items

Optional Products

Related Model

Description

Qty.

Summary of Contents for SmartPro Rackmount SMX1500XLRT2U

Page 1: ... that are individually switchable via software interface to reboot select equipment on demand or shed less significant loads to extend battery runtime for more critical equipment Supports simultaneous remote monitoring of UPS and site power conditions via built in USB and DB9 monitoring ports Includes PowerAlert UPS monitoring and unattended shutdown software with complete cabling Built in accesso...

Page 2: ...rgency Power Off EPO interface with cable Supports timed inverter shutoff after unattended shutdown activate self test and UPS output power control for delayed or immediate reboot of connected devices Supports Tripp Lite s WatchDog software application to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipment ideal for unatten...

Page 3: ...ont panel battery access door Battery replacement description Hot swappable user replaceable batteries VOLTAGE REGULATION Voltage regulation description Automatic voltage regulation AVR maintains line power operation with an input voltage range of 151 to 282 Overvoltage correction Input voltages between 245 and 282 are reduced by 12 Undervoltage correction Input voltages between 181 and 199 are bo...

Page 4: ...s in primary form factor height x width x depth cm 8 9 x 44 4 x 34 3 Installed whole system dimensions in secondary form factor height x width x depth cm 44 4 x 8 9 x 34 3 Rack Height 2U Secondary form factor Tower requires 2 9USTAND Installed whole system dimensions in secondary form factor height x width x depth inches 17 5 x 3 5 x 13 5 UPS dimensions in secondary form factor height x width x de...

Page 5: ...or remote applications LINE BATTERY TRANSFER Transfer time 2 4 milliseconds Low voltage transfer to battery power setpoint 151 High voltage transfer to battery power setpoint 282 SPECIAL FEATURES Grounding lug Back panel grounding lug Cold Start startup in battery mode during a power failure Cold start operation supported High availability UPS features Hot swappable batteries Green high efficiency...

Page 6: ...ring and control via SNMP Web or Telnet 1 U022 010 10 ft USB2 0 A B Gold Device Cable A Male to B Male 1 WATCHDOGSW WatchDog Service Monitoring Reboot Software 1 2 9USTAND Enables Tower Placement of Rackmount UPS Systems 1 2POSTRMKITWM Enables 2 Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems 1 MODBUSCARD For remote monitoring and control via MODBUS protocol 1 More informa...

Reviews: