background image

Maintains output within 3% of selected 208/120V or 240/120V nominal voltage during brownouts and overvoltages

Supports connected equipment during blackouts for 20/7 min. at half/full load levels; runtime is further expandable with optional external

battery packs (Model BP192V18-4U)

Some external battery configurations require the use of Tripp Lite's 

External Battery Configuration Software

 (see manual)

Network interfaces support simultaneous communications via DB9 port, USB port and SNMPWEBCARD slot. DB9 port supports RS-232

and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto shutdown features

of Windows and Mac OS X

Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus

any number of additional servers over IP

Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge

current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control

Built-in Emergency Power Off (EPO) interface with cable

Supports hardwire output at 208V and 120V

Split phase, four-conductor hardwire input connection on included detachable PDU

Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical

conditions

Front panel switches enable power on/off control, self-test and alarm cancel functions

Included adjustable mounting rails support installation in 4-post 19-in. rack enclosures

Optional 2-9USTAND tower stand set supports upright tower installation

Optional 2POSTRMKITWM accessory enables 2-post rackmount installation

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

$250,000 

Ultimate Lifetime Insurance

 (USA and Canada Only)

Specifications

OUTPUT

Output Volt Amp
Capacity (VA)

12000

Output kVA capacity
(kVA)

12

Output Watt Capacity
(watts)

8400

Output kW capacity

8.4

Output power factor

0.7

Output Capacity
Details

12,000 VA (240V) / 10,395 VA (208V) / 8,400 watts (208/240V)

Crest Factor

3:1

Nominal Output
Voltage(s) Supported

120V; 208V; 240V

Nominal Voltage
details

240/120V or 208/120V split phase output

Frequency
compatibility

60 Hz

Output voltage
regulation (line mode)

+/- 3%

Output voltage
regulation (Economy
line mode)

+/- 10%

Output voltage
regulation (Battery
mode)

+/- 3%