background image

overvoltages

Maintaints continuous operation through blackouts, voltage fluctuations and surges

Corrects line voltage conditions as low as 83V and as high as 145 back to selectable 100/110/120V nominal values

Standard internal battery set offers 16 minutes at half load (800w) and 6 minutes at full load (1600w)

Optional BP48V24-2U and BP48V60RT3U external rack/tower battery packs enable extended runtime operation

Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 19 inches

Ships with all mounting accessories for 4 post rackmount installation

Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation

Optional 2-9USTAND accessory enables small-footprint upright tower placement

Network interfaces support simultaneous communications via built-in USB, DB9 serial and SNMPWEBCARD slot

HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X

Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, with

the built-in ability to shutdown any number of additional servers over IP

UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current,

battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot

Built-in Emergency Power Off (EPO) interface with cable

NEMA 5-20P input plug (user-installable NEMA 5-15P replacement plug included) / NEMA 5-15R & NEMA 5-15/20R output receptacles

Integrated 3 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (Each

bank controls 1 outlet per load bank)

Front panel LEDs offer current monitoring and battery charge level information

UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required

$250,000 ULtimate Lifetime Insurance

Specifications

OUTPUT

Output Volt Amp
Capacity (VA)

2200

Output kVA capacity
(kVA)

2.2

Output Watt Capacity
(watts)

1600

Output kW capacity

1.6

Output power factor

0.7

Nominal Output
Voltage(s) Supported

100V; 110V; 120V

Nominal Voltage details

120V default (voltage selection via back panel dipswitches)

Frequency compatibility

50 / 60 Hz

Output voltage
regulation (line mode)

-14%, +6%

Output voltage
regulation (Battery mode)

+/- 5%

Built-in UPS output
receptacles

4 5-15R outlet(s); 4 5-15/20R outlet(s)

Built-in controllable
switched load banks

Three switchable single-outlet 5-15R load banks

Basic PDU options

PDU1220

 (1U / 13 5-15/20R outlets); 

PDUNV

 (1U / 2 C19, 12 C13 outlets); 

PDUV20

 (0U / 12 5-15/20R outlets);

PDU40TDUAL

 (0U / 40 5-15/20R outlets)

Metered PDU options

PDUMH20

 (1U / 13 5-15/20R outlets); 

PDUMH20

AT (1U / 16 5-15/20R outlets)*; 

PDUMV20

 (0U / 16 5-15/20R

outlets); 

PDUMV40

 (0U / 32 5-15/20R outlets)

Switched PDU options

PDUMH20ATNET

 (1U / 16 5-15/20R outlets)*; 

PDUMV20NET

 (0U / 24 5-15/20R outlets)

Reviews: