background image

Operation 

(continued)

“LINE” LED: 

This green light will turn continuously ON whenever connected equipment

is receiving utility-supplied AC power and your Inverter/Charger is set to 
“AUTO/REMOTE,” meaning that it will automatically switch to battery power if AC power
becomes unavailable. The light will flash intermittently when connected equipment is 
receiving utility power and your Inverter/Charger’s Operating Mode Switch is set to “CHRG
ONLY” to indicate that the Inverter/Charger’s inverter is OFF and that the Inverter/Charger
will not supply power from connected batteries.

“INV” LED: 

This yellow light will turn continuously ON whenever connected equipment is 

receiving battery-supplied AC power. It will flash if the Inverter/Charger does not detect the 
minimum load necessary to activate the inverter. 

“LOAD” LED: 

This red light will turn continuously ON when your Inverter/Charger is 

receiving utility-supplied AC power and the load is between 80% and 110% of capacity to 
alert you that the inverter might not be able to support the load. The light will flash 
intermittently after the Inverter/Charger's inverter shuts down due to a severe overload or 
overheating.

NOTE!: To remotely reset the Inverter/Charger after a shutdown due to overload, move

the  Remote Control Module’s “CONTROL” Switch to the “CHRG ONLY” or

“LINE/CHARGE ONLY”* position until the LOAD LED goes out. Remove the overload

by turning off some connected equipment. After allowing a few moments for the

Inverter/Charger to cool, switch the Remote Control Module’s “CONTROL” Switch back

to “AUTO” or “AUTO/INVERT”*. 

RJ45 Remote Ports: 

Use to connect the Remote Control Module to either an Inverter/Charger

or a second Remote Control Module. See Installation section.

Ignition Switch Control Jacks: 

Use to connect the Remote Control Module to your

vehicle’s ignition (with cable supplied on select models only) in order to automatically
control the Inverter/Charger with the vehicle’s ignition switch. See Installation section.

Mounting Holes/Slots: 

Front panel holes can be used either to attach included Mounting 

Plate or to mount Remote Control Module behind a panel. Top and side panel slots can be 
used to attach Remote Control Module (without the Mounting Plate) either under or along a
variety of surfaces with user-supplied hardware.

* “AUTO” and “CHRG ONLY” when used with lable; “AUTO/INVERT” and “LINE/CHARGE ONLY” when used with mounting plate.

Tripp Lite warrants its products to be free from defects in materials and workmanship for a period of one year (domestic) or 120 days

(export) from the date of initial purchase. Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option)

any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization (RMA) number from

Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with

transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place

of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been

altered or modified in any way. This warranty applies only to the original purchaser who must have properly registered the product within

10 days of purchase.

EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation or exclusion of implied

warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. 

EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR

CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH

DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment,

loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.

WARRANTY REGISTRATION

Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You'll be automatically entered into a

drawing for a chance to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series

number. The series number can be found on the product nameplate label, along with all required approval markings and information.

When requesting compliance information for this product, always refer to the series number. The series number should not be confused

with the marking name or model number of the product.

This product designed and engineered in the USA.

8

7

6

5

4

3

200603011  93-2236

1111 W. 35th Street  Chicago, IL 60609 USA • Customer Support: (773) 869-1234

www.tripplite.com

Copyright © 2006 Tripp Lite. All rights reserved. PowerVerter

®

is a registered trademark of Tripp Lite.

The policy of Tripp Lite is one of continuous improvement. Specifications are subject 

to change without notice.

INVERTER/CHARGER (APS, RV or EMS series)

CONTROL Switch: 

Move this switch to the “AUTO” or “AUTO/INVERT”* position to

have your Inverter/Charger provide connected equipment with AC power (converted from DC
power from attached batteries) in the event of an AC power outage. Move it to the “CHRG
ONLY” or “LINE/CHARGE ONLY”* position when equipment is not in use to conserve
battery power by disabling the inverter. The “LINE” LED will flash while the switch is in this
position to remind you that battery power will not be available in the event of a blackout or
disconnection from utility/shore power. In either position, the Inverter/Charger will supply AC
power to connected equipment and charge connected batteries while AC input is present.

“BATT VOLT/CHRG CURR” LEDs: 

These three lights will turn ON in several sequences

to show two separate operational conditions depending on the position of the CONTROL
Switch.

If the switch is in the “AUTO” or “AUTO/INVERT”* position, the LEDs indicate the
approximate charge level and voltage of your connected battery bank and alert you to several
fault conditions. See Chart 

for charge and voltage levels.

* “AUTO” and “CHRG ONLY” when used with lable; “AUTO/INVERT” and “LINE/CHARGE ONLY” when used with mounting plate.

BATTERY CHARGE INDICATION (Approximate)

CONTROL SWITCH IS IN THE "AUTO" OR “AUTO/INVERT” POSITION

LEDs Illuminated

Battery Capacity (Charging/Discharging)

Green

91%–Full

Green & Yellow

81%–90%

Yellow

61%–80%

Yellow & Red

41%–60%

Red

21%–40%

All three lights off

1%–20%

Flashing red

0% (Inverter shutdown)

††

Charge levels listed are approximate. Actual conditions vary depending on battery condition and load. 

††

Inverter shutdown protects battery against damage due to excessive discharge.

LEDs Illuminated

Fault Condition

All three lights 

Excessive discharge (Inverter shutdown)

flash slowly

All three lights 

Overcharge (Charger shutdown)

flash quickly

††

Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown protects battery 

against  damage due to excessive discharge. 

††

Approximately ¼ second on, ¼ second off. Charger shutdown 

protects battery against damage due to overcharge. May also indicate a battery charger fault exists.

If the switch is in the “CHRG ONLY” or “LINE/CHARGE ONLY”* position, the LEDs
indicate the approximate charge rate of the Inverter/Charger. See Chart 

for charge rates.

Note: the charge rates in the chart are expressed as percentages of the Inverter/Charger's rated
charging amps, which vary by model. Refer to the Inverter/Charger's Owner's Manual to
determine the charging amps of your specific model.

* “AUTO” and “CHRG ONLY” when used with lable; “AUTO/INVERT” and “LINE/CHARGE ONLY” when used with mounting plate.

CHARGE RATE INDICATION (Approximate)
CONTROL SWITCH IS IN THE "CHRG ONLY" OR “LINE/CHARGE ONLY” POSITION

LEDs Illuminated

Charge Rate

All three lights on

Overcharge error

Red

75% - 100%

Red & yellow

50% - 75%

Yellow

25% - 50%

Green

0% - 25%

All three lights off

0%

If all three lights remain on, an internal fault may exist. Turn off and disconnect the unit. Then, call Tripp Lite at 

(773) 869-1234 for assistance.

2B

2A

2

1

APS

J1

J2

A

UTO

SEE MANU

AL

1

2

3

6

7

4

5

8

8

8

8

Operation 

(continued)

“LOAD” LEDs:  

These three lights show the approximate load demand on your Inverter. 

See chart below for approximate load levels.

LEDs Illuminated

Approximate Load

Green

0% - 20%

Green & yellow

21% - 40%

Yellow

41% - 60%

Yellow & red

61% - 80%

Red

81% - Full

All three lights off

Inverter off

Flashing red

Overload

RJ45 Remote Ports:  

Use to connect the Remote Control Module to either an Inverter or a

second Remote Control Module. See Installation section.

Ignition Switch Control Jacks: 

Use to connect the Remote Control Module to your

vehicle’s ignition (with cable supplied on select models only) in order to automatically

control the Inverter with the vehicle’s ignition switch. See Installation section.

Mounting Holes/Slots:

Front panel holes can be used either to attach included Mounting

Plate or to mount Remote Control Module behind a panel. Top and side panel slots can be

used to attach Remote Control Module (without the Mounting Plate) either under or along a

variety of surfaces with user-supplied hardware. 

6

5

4

3

2A

2B

Limited Warranty

Module shown without mounting plate

200603011--APSRM2 Owner’s Manual Update.qxd  3/24/2006  3:22 PM  Page 2

Reviews: