Tripp Lite Protect It! SUPER7BTAA Owner'S Manual Download Page 2

2

SAVE THESE INSTRUCTIONS 

CAUTION! DO NOT connect to an ungrounded outlet. DO NOT use with 2-wire extension 

cords or adapters. This surge protector is designed for indoor use only. Install the 

surge protector away from heat-emitting appliances such as radiators or heat 

registers. Do not install where excessive moisture is present. Do not plug extension 

cords into it. Never install electrical, telephone, network or coaxial wiring during a 

lightning storm. Do not drill into any part of the housing or open the housing for any 

reason. There are no user-serviceable parts inside.

Important Safety Instructions

Installation

•  Use of this equipment in life support applications where failure of this equipment can 

reasonably be expected to cause the failure of the life support equipment or to significantly 
affect its safety or effectiveness is not recommended. 

Mount Your Surge Protector (Optional Installation. Available on Select Models Only):

 

If 

desired, mount your surge protector on a wall or other sturdy, vertical surface. However, you 

must mount the surge protector prior to connecting your equipment. Place a sheet of paper over 
the surge protector’s mounting holes and mark their centers with a push pin. Next, place this 

template over the desired area and mark with the push pins. Install screws (user supplied) into 
the marks until ¼ in. (0.6 cm) of the screw heads are exposed. Mount the surge protector over 

the screw heads and slide into place.

Connect Your Surge Protector to the AC Power Line:

 

Plug the surge protector’s power cord 

into a standard 3-wire grounded 120V AC outlet.

Turn Your Surge Protector ON:

 

Press the surge protector’s power switch to “ON” or “RESET” 

(depending on model). Select models feature an illuminated switch.

Check Your Surge Protector’s Diagnostic Indicator Lights (Available on Select Models 

Only): 

If your surge protector features diagnostic LEDs, check them prior to connecting your 

equipment. They will indicate various operating conditions when the surge protector is plugged 

into a live 120V AC outlet and the surge protector’s power switch is on.

“PROTECTED” LED:

 Indicates the surge suppression components are intact and providing 

complete protection against surges. If this LED does not illuminate, some of the surge 

suppression components are not functioning, and the unit should be replaced.  

Visit www.tripplite.com/support.

“GROUNDED” LED: 

Indicates wall outlet is grounded and surge protection can properly 

function. If this light DOES NOT illuminate and power is present, consult a qualified electrician 
to examine your outlet’s wiring.

“LINE OK” LED (select models): 

Indicates 120V AC power is present with no wiring faults 

detected.

Connect Your Equipment to the Surge Protector’s AC Outlets:

 

Plug your equipment’s power 

cords (including 2-wire devices) into the surge protector’s AC outlets. Select models feature 

integrated safety covers which cover the outlets when not in use. Other models feature special 

widely-spaced outlets to accommodate transformers without covering other outlets. DO NOT plug 
in extension cords. DO NOT OVERLOAD the surge protector’s outlets. The surge protector can 
accommodate a total equipment load of up to 15 amps (whether plugged into a single outlet or 

spread out over multiple outlets). If the load on the surge protector exceeds 15 amps, the circuit 
breaker* will trip and the outlets will stop providing power. If the circuit breaker trips, reduce the 
load by unplugging some devices. Depress the circuit breaker to reset.

* Circuit breakers are integrated into the power switch on select models and offered as a separate feature on other models.

18-08-292-932666.indb   2

9/12/2018   9:32:14 AM

Summary of Contents for Protect It! SUPER7BTAA

Page 1: ...9 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2018 Tripp Lite All rights reserved Protect It is a trademark of Tripp Lite PROTECT YOUR INVESTMENT Register your product...

Page 2: ...switch Check Your Surge Protector s Diagnostic Indicator Lights Available on Select Models Only If your surge protector features diagnostic LEDs check them prior to connecting your equipment They wil...

Page 3: ...urge protector must be plugged into a 3 wire grounded AC outlet for coaxial line surge protection to work 10 100 BaseT TX Token Ring Not compatible with PoE Power Over Ethernet applications Warranty a...

Page 4: ...tent needed of that provided by any coverage of connected equipment provided by other sources including but not limited to any manufacturer s warranty and or any extended warranties EXCEPT AS PROVIDED...

Page 5: ...idad Importantes 6 Instalaci n 6 Garant a Vitalicia Limitada 8 English 1 Fran ais 9 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2018 Todos los derechos reservados Prote...

Page 6: ...por el usuario en las marcas hasta que 0 6 cm de las cabezas de los tornillos est n visibles Monte el supresor de sobretensiones sobre las cabezas de tornillo y desl celo hasta que est en posici n Con...

Page 7: ...0NET protegen dispositivos en una sola l nea solamente Los modelos TLP810NET tienen un juego simple de conectores de tel fono RJ que protegen dispositivos en dos l neas El supresor de sobretensiones s...

Page 8: ...ESAMENTE TODOS LOS PERJUICIOS FORTUITOS Y RESULTANTES Ya que algunas jurisdicciones no permiten imponer limitaciones a la duraci n de una garant a impl cita o proh ben la exclusi n o limitaci n de da...

Page 9: ...10 Installation 10 Garantie a Vie 12 Police d assurance garantie vie totale 12 English 1 Espa ol 5 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2018 Tous droits r serv...

Page 10: ...des punaises Poser des vis fournies par l utilisateur dans les marques en laissant d passer les t te de vis de 0 6 cm Placer l liminateur de surtension sur les t te de vis et le faire glisser en plac...

Page 11: ...ction de ligne t l phonique l exception du TLP810NET prot gent des appareils sur une seule ligne Les mod les TLP810NET sont quip s d un seul ensemble de prises t l phoniques de type RJ qui prot gent d...

Page 12: ...ltant d une cause autre qu une transitoire de secteur Si l utilisateur satisfait aux exigences ci dessus Tripp Lite r parera ou remplacera la discr tion de Tripp Lite l quipement jusqu sa valeur sp ci...

Reviews: