Telephone or Telephone/Network Protection Jacks: 

These jacks 

protect your equipment against surges over a telephone line or 

telephone/network data line, depending on model. Connecting your 

equipment to these jacks is optional. Your UPS will work properly 

without this connection.

USB Port: 

The USB port connects your UPS to any USB workstation or 

server. Using this port, your UPS can communicate line-fail and low-

battery status. Use with Tripp Lite software and any USB cable to 
automatically save open files and shut down equipment during a 
blackout. Contact Tripp Lite Customer Support or consult your power 
protection software manual for more information.

Battery Replacement Door: 

Under normal conditions, the original 

battery in your UPS will last several years. Battery replacement should 
be performed only by qualified service personnel. Refer to "Battery 

Warnings" in the Safety section. Should your UPS require battery 

replacement, visit Tripp Lite on the Web at 

 

www.tripplite.com/support/battery/index.cfm to locate the specific 
replacement battery for your UPS.

Power Sensitivity/Lowline Adjustment: 

This dial is normally set fully 

counterclockwise, which enables the UPS to protect against waveform 
distortions in its AC input. When such distortion occurs, the UPS will 
normally switch to providing PWM sinewave power from its battery 
reserves for as long as the distortion is present. In some areas with 
poor utility power or where the UPS’s input power comes from a backup 

generator, frequent brownouts and/or chronic waveform distortion could 
cause the UPS to switch to battery too often, draining its battery 

reserves. You may be able to reduce how often your UPS switches to 
battery due to waveform distortion or brownouts by experimenting with 

different settings for this dial. As the dial is turned clockwise, the UPS 
becomes more tolerant of variations in its input power’s AC waveform 
and reduces the voltage point at which it switches to battery. NOTE: The 

further the dial is adjusted clockwise, the greater the degree of 
waveform distortion and the lower the input voltage the UPS will allow 
to pass to connected equipment. When experimenting with different 
settings for this dial, operate connected equipment in a safe test mode 

so that the effect on the equipment of any waveform distortions in the 

UPS’s output can be evaluated without disrupting critical operations. 
The experiment should last long enough to assure that all expected line 
conditions are encountered.

External Battery Connector (Select Models Only): 

Use to connect a 

single Tripp Lite external battery pack for additional runtime. The 
specifications section of this manual lists the Tripp Lite external battery 
pack that is compatible with select models. Refer to instructions 

available with the battery pack for complete connection information and 
safety warnings.

Basic Operation 

continued

NORM       DELAY

14-04-093-932248.indb   7

4/30/2014   4:47:40 PM

Summary of Contents for OmniSmart OMNIVS800

Page 1: ...applications 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite All rights reserved Important Safety Instructions 2 Quick Installation 3 Optional Installation...

Page 2: ...ors or extension cords to the output of your UPS This may damage the UPS and may affect the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not op...

Page 3: ...cal devices here The B outlets will provide surge protection only plug your printer and other non essential devices here Your UPS is designed to only support computer equipment You will overload the U...

Page 4: ...er and follow the installation instructions If PowerAlert Software and the appropriate cable did not come with your UPS you can obtain the software FREE via the Web at www tripplite com Any user suppl...

Page 5: ...olding the button until the alarm beeps several times and the UPS performs a self test See Results of a Self Test below Note you can leave connected equipment on during a self test Your UPS however wi...

Page 6: ...UPS OVERLOAD LED this red LED lights continuously and an alarm sounds after a self test to indicate the battery supported outlets are overloaded To clear the overload unplug some of your equipment fr...

Page 7: ...the distortion is present In some areas with poor utility power or where the UPS s input power comes from a backup generator frequent brownouts and or chronic waveform distortion could cause the UPS t...

Page 8: ...e UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service...

Page 9: ...nable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in...

Page 10: ...e para los usos m viles 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite Todos los derechos reservados Instrucciones de seguridad importantes 11 Instalaci n...

Page 11: ...nitroso No conecte supresores de sobretensiones ni cordones de extensi n a la salida de su UPS Esto puede da ar el UPS y afectar las garant as del supresor de sobretensiones y del UPS Advertencias sob...

Page 12: ...y otros dispositivos cr ticos Las B salidas proporcionar n protecci n contra sobretensiones solamente conecte aqu su impresora y otros dispositivos no esenciales Su UPS s lo est dise ado para dar sopo...

Page 13: ...ftware GRATUITAMENTE a trav s de la Web en www tripplite com Cualquier conector de entrada salida DB9 o un cable USB suministrado por el usuario pueden usarse para conectar su UPS a su computadora NOT...

Page 14: ...antenga presionado el bot n MUTE TEST Silencio Prueba durante uno segundo Nota Las alarmas continuas que le advierten apagar de inmediato el equipo conectado no pueden acallarse Para ejecutar una auto...

Page 15: ...tripplite com support battery index cfm para localizar la bater a de reemplazo Tripp Lite espec fica para su UPS LED OVERLOAD Sobrecarga Este LED rojo se enciende en forma continua y una alarma suena...

Page 16: ...tienen varios a os de vida til S lo deber reemplazar la bater a personal t cnico calificado V ase Advertencias sobre las bater as en la secci n sobre seguridad Si requiere reemplazar la bater a de su...

Page 17: ...erva por tanto tiempo como la distorsi n contin e En algunas reas con un suministro de energ a de la red de baja calidad o donde la energ a de entrada del UPS provenga de un generador de respaldo las...

Page 18: ...l nea se le solicitar n los n meros de serie y modelo de la unidad junto con otra informaci n general del comprador El n mero RMA y las instrucciones para el env o se le enviar n por correo electr ni...

Page 19: ...appropri aux applications mobiles 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite Tous droits r serv s Consignes de s curit importantes 20 Installation rapi...

Page 20: ...sth tique inflammable avec de l air de l oxyg ne ou de l oxyde nitreux Ne pas connecter des suppresseurs de surtension ou des cordons de rallonge la sortie de votre syst me d alimentation continue san...

Page 21: ...ies B assurent une protection contre les surtensions seulement branchez votre imprimante et autres accessoires moins importants ici Votre syst me d alimentation continue sans coupure est con u pour su...

Page 22: ...e c ble appropri ne sont pas joints votre UPS vous pouvez obtenir le logiciel GRATUITEMENT par le Web www tripplite com N importe quelle connexion DB9 ou c ble USB fourni par l utilisateur peuvent alo...

Page 23: ...alimentation continue sans coupure presser et maintenir enfonc le bouton MUTE TEST pendant une seconde Remarque les alarmes continuelles vous avertissant de d connecter imm diatement les quipements b...

Page 24: ...tripplite com support index cfm pour d terminer la batterie de remplacement Tripp Lite pour votre syst me d alimentation continue sans coupure DEL OVERLOAD Cette DEL rouge reste allum e et une alarme...

Page 25: ...tion continue sans coupure normalement passe l alimentation onde sinuso dale PWM depuis ses r serves de batterie aussi longtemps que la distorsion est pr sente Dans des lieux avec une mauvaise aliment...

Page 26: ...dale PWM suppression de la surtension c a sup rieure IEEE 587 Cat A B standards att nuation du bruit c a 40 dB 1MHz modes de protection c a H N H G N G la p riode d ex cution de la pile pour l OMNIVS...

Page 27: ...ssite une r paration visitez www tripplite com support et cliquez sur le lien Product Returns retour du produit De cet endroit vous pouvez demander un num ro d autorisation de retour de mat riel RMA q...

Page 28: ...28 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 14 04 093 93 2248_RevD 14 04 093 932248 indb 28 4 30 2014 4 47 51 PM...

Reviews: