background image

4

These connections are optional. Your UPS will function properly without these connections.

Optional Installation

1

  Phone Line or Phone/Network Line 

Surge Suppression

Your UPS has jacks which protect against surges 
on a phone line. Select models feature jacks 

which also protect against surges on a network 

line. Using appropriate telephone or network 

cords, connect your wall jack to the UPS jack 

marked “IN.” Connect your equipment to the UPS 
jack marked “OUT.” Make sure the equipment you 
connect to the UPS’s jacks is also protected 
against surges on the AC line. 

Not compatible with 

PoE (Power over Ethernet) applications.

2

   USB or DB9 Communication 

 

Port (select models only): 

These ports can connect your UPS to any 

computer for automatic file saves and unattended 

shutdown in the event of a power failure. Use with 
Tripp Lite's PowerAlert Software and appropriate 
USB or DB9 cable. A PowerAlert CD and USB or 

DB9 cable may be included with your UPS; if so, 
insert the CD into the CD tray of your computer 

and follow the installation instructions. If 
PowerAlert Software and the appropriate cable did 

not come with your UPS, you can obtain the 
software FREE via the Web at www.tripplite.com. 
Any user-supplied DB9 pass

-

through or USB cable 

may then be used to connect your UPS to your 

computer. 

NOTE: This connection is optional. The 

UPS will work properly without this connection.

3

   External Battery Connection

 

(select models)

All UPS models come with a robust internal battery 
system; select models feature connectors that 
accept an optional external battery pack (sold 
separately from Tripp Lite*) to provide additional 

runtime. Adding an external battery will increase 
recharge time as well as runtime. See battery pack 
owner’s manual for complete installation 
instructions. Make sure cables are fully inserted 

into their connectors. Small sparks may result 
during battery connection; this is normal. Do not 
connect or disconnect battery pack when the UPS 
is running on battery power.

* See Specifications section for battery pack available for 
your specific UPS model.

NORM       DELAY

1

NORM       DELAY

2

NORM       DELAY

3

OMNIVS1500XL shown

OMNIVS1500XL shown

OMNIVS1500XL shown

14-04-093-932248.indb   4

4/30/2014   4:47:38 PM

Summary of Contents for OmniSmart OMNIVS800

Page 1: ...applications 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite All rights reserved Important Safety Instructions 2 Quick Installation 3 Optional Installation...

Page 2: ...ors or extension cords to the output of your UPS This may damage the UPS and may affect the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not op...

Page 3: ...cal devices here The B outlets will provide surge protection only plug your printer and other non essential devices here Your UPS is designed to only support computer equipment You will overload the U...

Page 4: ...er and follow the installation instructions If PowerAlert Software and the appropriate cable did not come with your UPS you can obtain the software FREE via the Web at www tripplite com Any user suppl...

Page 5: ...olding the button until the alarm beeps several times and the UPS performs a self test See Results of a Self Test below Note you can leave connected equipment on during a self test Your UPS however wi...

Page 6: ...UPS OVERLOAD LED this red LED lights continuously and an alarm sounds after a self test to indicate the battery supported outlets are overloaded To clear the overload unplug some of your equipment fr...

Page 7: ...the distortion is present In some areas with poor utility power or where the UPS s input power comes from a backup generator frequent brownouts and or chronic waveform distortion could cause the UPS t...

Page 8: ...e UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service...

Page 9: ...nable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in...

Page 10: ...e para los usos m viles 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite Todos los derechos reservados Instrucciones de seguridad importantes 11 Instalaci n...

Page 11: ...nitroso No conecte supresores de sobretensiones ni cordones de extensi n a la salida de su UPS Esto puede da ar el UPS y afectar las garant as del supresor de sobretensiones y del UPS Advertencias sob...

Page 12: ...y otros dispositivos cr ticos Las B salidas proporcionar n protecci n contra sobretensiones solamente conecte aqu su impresora y otros dispositivos no esenciales Su UPS s lo est dise ado para dar sopo...

Page 13: ...ftware GRATUITAMENTE a trav s de la Web en www tripplite com Cualquier conector de entrada salida DB9 o un cable USB suministrado por el usuario pueden usarse para conectar su UPS a su computadora NOT...

Page 14: ...antenga presionado el bot n MUTE TEST Silencio Prueba durante uno segundo Nota Las alarmas continuas que le advierten apagar de inmediato el equipo conectado no pueden acallarse Para ejecutar una auto...

Page 15: ...tripplite com support battery index cfm para localizar la bater a de reemplazo Tripp Lite espec fica para su UPS LED OVERLOAD Sobrecarga Este LED rojo se enciende en forma continua y una alarma suena...

Page 16: ...tienen varios a os de vida til S lo deber reemplazar la bater a personal t cnico calificado V ase Advertencias sobre las bater as en la secci n sobre seguridad Si requiere reemplazar la bater a de su...

Page 17: ...erva por tanto tiempo como la distorsi n contin e En algunas reas con un suministro de energ a de la red de baja calidad o donde la energ a de entrada del UPS provenga de un generador de respaldo las...

Page 18: ...l nea se le solicitar n los n meros de serie y modelo de la unidad junto con otra informaci n general del comprador El n mero RMA y las instrucciones para el env o se le enviar n por correo electr ni...

Page 19: ...appropri aux applications mobiles 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2014 Tripp Lite Tous droits r serv s Consignes de s curit importantes 20 Installation rapi...

Page 20: ...sth tique inflammable avec de l air de l oxyg ne ou de l oxyde nitreux Ne pas connecter des suppresseurs de surtension ou des cordons de rallonge la sortie de votre syst me d alimentation continue san...

Page 21: ...ies B assurent une protection contre les surtensions seulement branchez votre imprimante et autres accessoires moins importants ici Votre syst me d alimentation continue sans coupure est con u pour su...

Page 22: ...e c ble appropri ne sont pas joints votre UPS vous pouvez obtenir le logiciel GRATUITEMENT par le Web www tripplite com N importe quelle connexion DB9 ou c ble USB fourni par l utilisateur peuvent alo...

Page 23: ...alimentation continue sans coupure presser et maintenir enfonc le bouton MUTE TEST pendant une seconde Remarque les alarmes continuelles vous avertissant de d connecter imm diatement les quipements b...

Page 24: ...tripplite com support index cfm pour d terminer la batterie de remplacement Tripp Lite pour votre syst me d alimentation continue sans coupure DEL OVERLOAD Cette DEL rouge reste allum e et une alarme...

Page 25: ...tion continue sans coupure normalement passe l alimentation onde sinuso dale PWM depuis ses r serves de batterie aussi longtemps que la distorsion est pr sente Dans des lieux avec une mauvaise aliment...

Page 26: ...dale PWM suppression de la surtension c a sup rieure IEEE 587 Cat A B standards att nuation du bruit c a 40 dB 1MHz modes de protection c a H N H G N G la p riode d ex cution de la pile pour l OMNIVS...

Page 27: ...ssite une r paration visitez www tripplite com support et cliquez sur le lien Product Returns retour du produit De cet endroit vous pouvez demander un num ro d autorisation de retour de mat riel RMA q...

Page 28: ...28 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 14 04 093 93 2248_RevD 14 04 093 932248 indb 28 4 30 2014 4 47 51 PM...

Reviews: