Front Panel:

Rear Panel:

Product Features

1

 

Gigabit Ethernet Ports:

 These 24 twisted-pair RJ-45 ports support auto-negotiable 

10/100/1000 Mbps and auto MDI/MDIX cross-over detection functions for true “plug and 
play” capability. 

 

Note: 

Not compatible with PoE (Power Over Ethernet) applications.

2

 

Power ON/OFF LED:

 An LED illuminates to indicate that the switch is receiving power.

3

 

Port Status LEDs: 

These 24 green LEDs illuminate to indicate the link speed. The LED will 

be off for 10 Mbps and solid green for 100 Mbps and 1000 Mbps. There are also 24 yellow 
LEDs that blink to indicate activity on each port.

 

4

 

NEMA 5-15R Outlets: 

This switch includes 12 NEMA 5-15R receptacles.

5

 

Circuit Breaker: 

If the current drawn by the equipment connected to the PDU exceeds the 

Maximum Load Rating, the 12A thermal circuit breaker will trip to prevent possible damage 

and its plunger will pop up. If this happens, disconnect excess equipment and allow the 
breaker to cool at least one minute before depressing the plunger to reset the unit.

6

 

Input:

 AC power input from a connected UPS system or alternate source.

7

 

Grounding Lug: 

Use this screw to connect other equipment to ground.

1

3

4

5

6

2

7

15-02-230-9333C6.indd   4

2/23/2015   11:16:07 AM

Summary of Contents for NSU-G24

Page 1: ... Network Switch with Built in PDU Model NSU G24 Series Number AG 00C6 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2015 Tripp Lite All rights reserved 15 02 230 9333C6 indd 1 2 23 2015 11 16 06 AM ...

Page 2: ...ation can cause product damage that is not covered by the warranty Do not expose the network switch s connected networking cables to outdoor elements Do not use this product near water e g in a wet basement or near a swimming pool PDU Switch Connection Warnings Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the ...

Page 3: ...utateur réseau aux éléments extérieurs Ne pas utiliser ce produit à proximité de l eau p ex dans un sous sol humide ou à proximité d une piscine Avertissement concernant la connexion de la PDU du commutateur Il n est pas recommandé d utiliser cet équipement dans les applications de soutien vital où une panne de cet équipement serait susceptible de causer une panne de l équipement de soutien vital ...

Page 4: ...bps and 1000 Mbps There are also 24 yellow LEDs that blink to indicate activity on each port 4 NEMA 5 15R Outlets This switch includes 12 NEMA 5 15R receptacles 5 Circuit Breaker If the current drawn by the equipment connected to the PDU exceeds the Maximum Load Rating the 12A thermal circuit breaker will trip to prevent possible damage and its plunger will pop up If this happens disconnect excess...

Page 5: ...the rackmount screws to hold the unit in the rack before installation 2 Connect the switch to a properly grounded outlet The POWER LED will illuminate when the switch turns on 3 Connect the network cables to the network switch 4 Connect equipment to the PDU outlets Make sure the load connected does not exceed the PDU s circuit breaker rating 3 4 2 1 A C C A B B D D 15 02 230 9333C6 indd 5 2 23 201...

Page 6: ...ance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marketing name or model number of th...

Page 7: ...7 Notes 15 02 230 9333C6 indd 7 2 23 2015 11 16 08 AM ...

Page 8: ...8 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 15 02 230 93 33C6_RevA 15 02 230 9333C6 indd 8 2 23 2015 11 16 09 AM ...

Reviews: