Tripp Lite N785-H01-SCMM Quick Start Manual Download Page 6

6

LED Status Table

Link Fault Signaling (LFS)

The LFS LED will indicate when a cable has been severed or when 

some other cause of disruption in service has occurred. The LFS function 

monitors both copper and fiber segments for a total service report. Set 

DIP Switch 1 (LFS) to ON for normal operational use and to OFF when 

installing cables or when testing the network connection.

Loop Back Test

Each media converter features DIP switches to activate both local and 

remote loopback diagnostic test functions. Use the Local Loop Back 

(LLB) function to check if the copper segment is connected properly. Use 

the Remote Loop Back (RLB) function to check if the fiber segment is 

connected properly. 

Note: 

When enabling loopback testing in one segment of the connection the 

other segment will be blocked until the loopback is disabled.

21-09-096-933F71-EN.indd   6

21-09-096-933F71-EN.indd   6

9/13/2021   9:17:46 AM

9/13/2021   9:17:46 AM

Summary of Contents for N785-H01-SCMM

Page 1: ...pplite com support Copyright 2021 Tripp Lite All rights reserved Este manual est disponible en espa ol en la p gina de Tripp Lite tripplite com Ce manuel est disponible en fran ais sur le site Web de...

Page 2: ...t Signaling LFS and Reserve functions Link Fault Signaling LFS LED indicates when a cable has been severed or another cause for disruption has occurred Local Loop Back LLB tests the copper network con...

Page 3: ...onnections are the same for the N785 H01 SCSM with only the specs being different See the Specifications section in this manual for details on your media converter To avoid damage due to Electrostatic...

Page 4: ...d for a copper to fiber installation The following installation instructions refer to the N785 H01 SFP Connections are the same for all models with only the specs being different See the Specification...

Page 5: ...unit is not powered on ALM Red On LFS enabled and link fault occurred ALM Red Off LFS disabled or no link fault occurred RJ45 1000 Green On Copper connection up to 1000 Mbps 1000 Green Off Copper con...

Page 6: ...network connection Loop Back Test Each media converter features DIP switches to activate both local and remote loopback diagnostic test functions Use the Local Loop Back LLB function to check if the c...

Page 7: ...02 3u 100Base TX FX IEEE 802 3ab 1000Base T IEEE 802 3z 1000Base SX LX IEEE 802 3 Auto Negotiation Power Consumption 1 8W Power Supply Input 100 240VAC 50 60 Hz 0 5A Power Supply Output 12VDC 1 5A Ope...

Page 8: ...ould take care to determine prior to use whether this device is suitable adequate or safe for the use intended Since individual applications are subject to great variation the manufacturer makes no re...

Reviews: