2

Installation

Positioning Your Surge Suppressor:

 Place your monitor or notebook computer directly on the 

surge suppressor.

Note: 

A mat is included with your MT-6PLUS to protect the surface finish of the surge suppressor. Please put it 

on top of the surge suppressor prior to positioning your monitor or notebook computer.

Connect Your Surge Suppressor to Your AC Power Line: 

The Surge Suppressor's power cord 

should only be connected to a standard 3-wire grounded 120V AC 60 Hz outlet. 

Activate  Your  Surge  Suppressor's  Switches: 

The "MASTER" switch simultaneously controls 

power to all outlets (except the outlet labeled "UNSWITCHED" or "ALWAYS ON"). The other switches 
control power to their individual corresponding outlets on the rear panel. The "MASTER" switch 

must be ON for the individual switches to work. The outlet labeled "COMPUTER" does not have an 

individual front panel switch; it is controlled by the "MASTER" switch. The switch indicator lights will 
illuminate when their corresponding switches are ON. 
The outlet labeled "UNSWITCHED" or "ALWAYS ON" is not controlled by any of the front panel 
switches, even the "MASTER" switch. It provides power (as long as it is available at the wall outlet) 

for equipment you always need ON, including routers or modems. Outlets are labeled only for your 
convenience. It is not necessary, for example, to connect a printer to an outlet labeled PRINTER. 
Any type of equipment (as long as it does not exceed 15 amps) can be plugged into any of the 
outlets. 

Check Your Surge Suppressor's Diagnostic Indicator Lights: 

The diagnostic LEDs will indicate 

various operating conditions when the surge suppressor is plugged into a live 120 VAC outlet and 

the "MASTER" switch is ON. 

"PROTECTED" or "SURGE PROTECTED" LED: 

Indicates the surge suppression components are 

intact and providing complete protection against spikes and surges. If this LED does not 

illuminate, some of the surge suppression components are not functioning and the unit should 

be replaced. Visit www.tripplite.com/support for assistance.

“GROUNDED” LED (select models):

 Indicates wall outlet is grounded and surge protection can 

function. If this light DOES NOT illuminate and power is present, consult a qualified electrician 
to examine your outlet’s wiring.

"LINE OK" LED: 

Indicates 120V AC power is present with no wiring faults detected. 

Connect  AC  Equipment  to  Your  Surge  Suppressor:

 Connect the AC power cords of your 

equipment, including any 2-wire devices. Do not plug extension cords into it. DO NOT OVERLOAD 

the Surge Suppressor. Each outlet can handle up to 15 amps, but do not exceed a total load of 

more than 15 amps for all outlets. If the circuit breaker trips, the outlets will cease to provide 

power. Remove overload and depress circuit breaker to reset.

Connect Your Surge Suppressor to Your Telephone Line:

 Connect the phone cord from the wall 

jack directly to the Surge Suppressor phone jack labeled "IN." Connect the phone cord (provided) 

from the device to be protected directly to the phone jack labeled "OUT." The Surge Suppressor 

must always be the first item connected in line from the telephone wall jack. The Surge Suppressor 

must be plugged into a 3-wire grounded outlet to work.

USB Charging Ports (MT-6PLUS only):

 Two USB charger ports are capable of delivering up to 2.1 

A total. This will provide enough power to charge the most demanding devices, including 

smartphones, tablets and MP3 players.

Note: 

The charger ports are controlled by the master power switch of the unit.

13-04-225-9332B7.indb   2

5/29/2013   3:56:23 PM

Summary of Contents for MT-6PLUS

Page 1: ...outlet DO NOT use with 2 wire extension cords or adapters This surge suppressor is designed for indoor use only Install the surge suppressor away from heat emitting appliances such as radiators or heat registers Do not install where excessive moisture is present Do not plug extension cords into it Never install electrical telephone network or coaxial wiring during a lightning storm Do not drill in...

Page 2: ...120 VAC outlet and the MASTER switch is ON PROTECTED or SURGE PROTECTED LED Indicates the surge suppression components are intact and providing complete protection against spikes and surges If this LED does not illuminate some of the surge suppression components are not functioning and the unit should be replaced Visit www tripplite com support for assistance GROUNDED LED select models Indicates w...

Page 3: ...pping or delivery charges prepaid to Tripp Lite 1111 W 35th St Chicago IL 60609 Seller will pay return shipping charges The warranties of all TRIPP LITE surge suppressors are null and void if they have been connected to the output of any UPS system The warranties of all TRIPP LITE UPS Systems are null and void if a surge suppressor has been connected to its output receptacles THIS WARRANTY DOES NO...

Page 4: ...ce is not provided including but not limited to lack of a proper safety ground Telephone service equipment must also include a properly installed and operating primary protection device at the telephone service entrance such devices are normally added during telephone line installation All above warranties are null and void if the Tripp Lite product has been improperly installed tampered with or a...

Page 5: ...techo Instale el supresor de sobretensiones lejos dedispositivos emisores de calor como radiadores o registros de calor No lo instale donde haya excesiva humedad No conecte cordones de extensión Nunca instale ningún cableado eléctrico telefónico de red o coaxial durante una tormenta eléctrica No taladre en ninguna parte de lacubierta ni la abra por ningún motivo No hay partes que requieran manteni...

Page 6: ...tomas de corrientes están etiquetadas únicamente para su conveniencia No es necesario por ejemplo conectar la impresora a la salida etiquetada PRINTER Impresora Cualquier tipo de equipo En tanto no exceda de 15 amps puede ser conectado a cualquiera de las tomas de corriente Revise las Luces de Diagnóstico de su Supresor Los LEDs de diagnóstico indicarán varias condiciones de operación cuando el Su...

Page 7: ...ectado en línea de el contacto para línea telefónica de la pared El Supresor de Picos debe conectarse a una toma de corriente de 3 hilos debidamente conectada a tierra para trabajar Puertos de Carga USB MT 6PLUS solamente Dos puertos USB de carga son capaces de entregar un total de hasta 2 1A Esto proporcionará suficiente energía para cargar los dispositivos más demandantes incluyendo teléfonos in...

Page 8: ...IALIZACIÓN O IDONEIDAD ESTÁ LIMITADA AL PLAZO ENUNCIADO ANTERIORMENTE ESTA GARANTÍA EXCLUYE EXPRESAMENTE TODOS LOS PERJUICIOS FORTUITOS Y RESULTANTES Ya que algunas jurisdicciones no permiten imponer limitaciones a la duración de una garantía implícita o prohíben la exclusión o limitación de daños fortuitos o resultantes puede que las limitaciones o exclusiones antedichas no rijan en todos los cas...

Page 9: ...ler cet éliminateur de surtension loin d appareils de chauffage comme des radiateurs ou des registres de chaleur Ne pas installer en présence d humidité excessive Ne pas y brancher de cordons prolongateurs Ne jamais faire l installation de câblage électrique téléphonique réseau ou coaxial pendant un orage Ne jamais percer une quelconque partie du boîtier ni ouvrir le boîtier Aucune pièce interne n...

Page 10: ...errupteur principal est ouvert DEL PROTECTED ou SURGE PROTECTED Protégé contre les surtensions Indique que les éléments de parasurtension sont intacts et offrent une protection complète contre les brusques variations et les surtensions Si cette DEL ne s allume pas certains composants de la parasurtension ne fonctionnent pas et il faut remplacer l appareil Visitez www tripplite com support pour obt...

Page 11: ...SUSMENTIONNÉE LAPRÉSENTE GARANTIE EXCLUT EXPRESSÉMENT TOUS LES DOMMAGES FORTUITS ET INDIRECTS Certaines juridictions n autorisant pas de limitation de la durée de la garantie implicite et d autres l exclusion ou la limitation des dommages fortuits ou indirects les limitations et exclusions mentionnées ci dessus peuvent ne pas s appliquer à votre cas La présente garantie vous donne des droits spéci...

Page 12: ... n est pas fourni y compris mais sans y être limité l absence d une mise à la terre sécuritaire L équipement téléphonique doit également inclure un appareil de protection primaire correctement installé et en état de marche à l entrée du service téléphonique de tels appareils sont normalement ajoutés lors de l installation d une ligne téléphonique Toutes les garanties ci dessus sont nulles et non a...