overload protection and lighted power switch.
Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Specifications
OVERVIEW
Amp Capacity
2.1A at 120V AC
Efficiency
96%
Form Factor
Small tower format
Input Plug Type
NEMA 5-15P-HG
Leakage Current
Less than 100 microamps
Let-through Voltage
(Combination Wave)
L-N: 250V L-G: 250V N-G: 0.5V
Let-through Voltage (Ring
Wave)
L-N: 20V L-G: 20V N-G: 0.5V
Noise Suppression Rating
35-65 DB
Nominal Voltage / Frequency
120V/60Hz
Output Receptacle Qty / Type
2 NEMA 5-15R-HG
Over Current Protection
2A circuit breaker
Shipping Weight
13.80 lbs. / 6.26 kg
Suppression Joule Rating
940 joules
Surge Test Conditions
Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms
Total Harmonic Distortion
Less than 1%
Transformer Type
Medical grade, low impedance transformer-based line isolation transformer
Unit Dimensions (HWD/in.)
4.5 x 4.75 x 7.75
VA / Watt Capacity
250
INPUT
Input cord length (ft.)
6
Input cord length (m)
1.83
PHYSICAL
Cooling method
Convection
Unit Dimensions (HWD/cm)
11.43 x 12.07 x 19.69
CERTIFICATIONS
Certifications
Tested to UL60601-1
WARRANTY
Product Warranty Period
(Worldwide)