4. Setup

Caution! Read All Instructions and Warnings Before Installation!   

Warning: Charging stations can be extremely heavy. Do not attempt to unpack the charging station without assistance. Follow 

the unpacking instructions document that shipped with this product before proceeding with setup. Use extreme caution when 

handling the charging station and be sure to follow all handling and installation instructions. Do not attempt to install 

equipment without first stabilizing the charging station.

4.1 Power Requirements

4.2 Installing the Handle Bracket and Power Cord Manager

4.3 Adjusting Storage Shelf Dividers

The charging station can be plugged into an AC outlet with a dedicated circuit. An AC outlet with a 20-amp (NEMA 5-20R) AC circuit is recommended 

for powering the charging station. The AC outlet used to power the charging station should not be shared. The total wattage of the charging station and 
all connected components should not exceed 1440 watts.

To install the handle bracket, use the included hex key tool to attach four (4) hex screws to the charging station cabinet 

A

. To install the cord 

manager, use the same hex key tool to secure the eight (8) hex screws that attach the cord manager brackets (four per bracket) to the charging 
station cabinet 

B

Your charging station comes with two storage shelves with adjustable dividers that can 

each accommodate up to 16 personal electronic devices per shelf.
Remove any personal electronic devices stored on the shelf tray. Then remove the 

blanking panel. To remove the shelf tray from the cabinet, push the shelf tray forward 

to disengage from the mounting hook, then pull the tray up and out. Once the shelf is 

removed, remove or rearrange a spring-wire divider by first pulling it gently forward to 

disengage it from the rear end 

A

, then pull it up from the front of the tray 

B

. Repeat 

as necessary for additional shelf dividers.

A

B

B

A

Summary of Contents for CSC32ACWHG

Page 1: ...t Light Operation 6 6 Specifications 7 7 Storage Service and Cleaning 7 8 Warranty and Product Registration 8 Espa ol 9 Fran ais 17 Hospital Grade Charging Station Cart with Anti Microbial Coating and...

Page 2: ...equate space around the charging station for proper ventilation Do not block cover or insert objects into the charging station s external ventilation openings The charging station is extremely heavy U...

Page 3: ...Panels Removable 4 Reversible Handle 5 Swivel Locking Casters 6 Power Cord Manager 7 Power Cord Access Holes 1 Located on Each Side 8 5 15P HG Hospital Grade Input Plug with 10 ft Cord 9 Padlock Hasp...

Page 4: ...uld not be shared The total wattage of the charging station and all connected components should not exceed 1440 watts To install the handle bracket use the included hex key tool to attach four 4 hex s...

Page 5: ...unit s receptacles B then run the power connector through the storage shelf s power cord opening to establish a power connection C Repeat for all devices and reattach the blanking panels With the bot...

Page 6: ...off and the timer will be reset for the next sanitizing cycle Note Both charging station doors must be closed before the start button is pressed The UV lights will not turn on if either door is open...

Page 7: ...n a controlled indoor environment away from moisture temperature extremes flammable liquids and gasses conductive contaminants dust and direct sunlight Store the enclosure in its original shipping con...

Page 8: ...pliance information for this product always refer to the series number The series number should not be confused with the marketing name or model number of the product FCC Notice Class B This device co...

Page 9: ...enamiento 4 4 Conexi n de Dispositivos y 13 Alimentaci n de la Unidad de CA 4 5 Cerraduras de las Puertas 13 5 Operaci n con Luz Ultravioleta 14 6 Especificaciones 15 7 Almacenamiento Servicio 15 y Li...

Page 10: ...ci n apropiada No bloquee cubra ni coloque objetos en las aberturas externas de ventilaci n de la estaci n de carga La estaci n de carga es muy pesada Tenga cuidado cuando maneje la estaci n de carga...

Page 11: ...n capacidad para almacenar hasta 16 dispositivos por estante 3 Paneles obturadores removibles 4 Manija reversible 5 Ruedas giratorias con bloqueo 6 Administrador del Cable de Alimentaci n 7 Orificios...

Page 12: ...e la estaci n de carga y todos los componentes conectados no debe superar los 1440 Watts Para instalar el soporte de la manija utilice la llave hexagonal incluida para colocar cuatro 4 tornillos hexag...

Page 13: ...de la abertura del cable del estante para establecer la conexi n el ctrica C Repita el procedimiento para todos los dispositivos y vuelva a colocar los paneles obturadores Con el panel obturador infe...

Page 14: ...ciar para el siguiente ciclo de sanitizado Nota Ambas puertas de la estaci n de carga deben cerrarse antes de oprimir el bot n de arranque Las luces UV no se encender n si cualquiera de las puertas es...

Page 15: ...te debe guardarse en un entorno interior controlado lejos de humedad excesiva temperaturas extremas l quidos y gases inflamables contaminantes conductores polvo o luz solar directa De ser posible alma...

Page 16: ...que es posible que las limitaciones anteriores no se apliquen a usted Esta garant a le otorga derechos legales espec ficos y usted puede tener otros derechos que pueden variar de una jurisdicci n a ot...

Page 17: ...4 4 Raccordement des dispositifs et 21 mise sous tension de l appareil CA 4 5 Verrous de porte 21 5 Fonctionnement du rayonnement 22 ultraviolet 6 Caract ristiques techniques 23 7 Entreposage entretie...

Page 18: ...externes de la station de chargement La station de chargement est extr mement lourde Faire preuve de vigilance lors de la manutention de la station de chargement Ne pas tenter de la d baller sans ass...

Page 19: ...ign e r versible 5 Roulettes orientables verrouillables 6 Guide du cordon d alimentation 7 Trous d acc s au cordon d alimentation 1 de chaque c t 8 Fiche d entr e approuv e pour les h pitaux 5 15P HG...

Page 20: ...partag e La puissance totale de la station de chargement et de tous les composants branch s ne devrait pas exc der 1 440 watts Pour installer le support de la poign e utiliser la cl hexagonale inclus...

Page 21: ...mentation travers l ouverture pour le cordon d alimentation de l tag re de rangement pour tablir une connexion de l alimentation C R p ter pour tous les appareils et remettre les panneaux de suppressi...

Page 22: ...on Remarque Les deux portes de la station de chargement doivent tre ferm es avant d enfoncer le bouton de d marrage Les lumi res UV ne s allumeront pas si l une des portes est ouverte Cela permet d as...

Page 23: ...contr l l cart de l humidit des temp ratures extr mes des liquides et des gaz inflammables des contaminants conducteurs de la poussi re et de la lumi re directe du soleil Entreposer le bo tier dans so...

Page 24: ...ons ou exclusions susmentionn es peuvent ne pas s appliquer vous Cette garantie vous accorde des droits l gaux sp cifiques et vous pouvez avoir d autres droits qui varient d une comp tence l autre AVE...

Reviews: