Tripp Lite APS 2012 INT Owner'S Manual Download Page 4

4R

Operation 

(continued)

Indicator Lights

Your Inverter (as well as an optional Tripp Lite Remote Control Module) is equipped with a simple, intuitive, user-friendly set of indicator lights. These
easily-remembered “traffic light” signals will allow you, shortly after first use, to tell at a glance a wide variety of operating details.

“BATT VOLT” or “BATT VOLT/CHRG CURR” LEDs: 

Depending on your model, this set of three LEDs will display different operating information.

750 and 1250 models:

Whether the switch is in the “AUTO/REMOTE” or “CHARGE ONLY” position, the LEDs indicate the approximate charge level

and voltage of your connected battery bank and alert you to several fault conditions. See “BATT VOLT” LED Function Chart for details.

2012 and 3012 models only:

If the switch is in the “AUTO/REMOTE” position, the LEDs indicate the approximate charge level and voltage of your

connected battery bank and alert you to several fault conditions. See “BATT VOLT” LED Function Chart for details.

If the switch is in the “CHARGE ONLY” position, the LEDs indicate the approximate charge rate of the Inverter. See “CHRG CURR” LED Function Chart
for details. Note: the charge rates in the chart are expressed as percentages of the Inverter's rated charging amps. Refer to the specifications to determine
the charging amps of your specific model.

“LINE Green LED”:

If the operating mode switch is set

to “AUTO/REMOTE”, this light will ILLUMINATE
CONTINUOUSLY when your vehicle is connected to
shore (or generator) power.

If the operating mode switch is set to “CHARGE ONLY”,
this light will BLINK to alert you that the unit’s inverter is OFF and will
NOT supply AC power in the absence of a utility/generator source.

“INV” (Inverting) Yellow LED: 

This light will

ILLUMINATE CONTINUOUSLY whenever connected
equipment is receiving battery-supplied, inverted AC
power.

“LOAD” Red LED: 

This red light will ILLUMINATE

CONTINUOUSLY whenever the inverter is functioning
and the power demanded by connected equipment exceeds
100% of load capacity. The light will BLINK to alert you
when the inverter shuts down due to a severe overload or
overheating. If this happens, turn the operating mode switch “OFF”;
remove the overload and let the unit cool. You may then turn the operating
mode switch to either “AUTO/REMOTE” or “CHARGE ONLY” after it
has adequately cooled. 

“BATT VOLT” LED Function Chart (All models)

Approximate Battery Charge Level*

LEDs

Battery Capacity

Illuminated

(Charging/Discharging)

Green

91%–Full

Green & Yellow

81%–90%

Yellow

61%–80%

Yellow & Red

41%–60%

Red

21%–40%

All three lights off

1%–20%

Flashing red

0% (Inverter 
shutdown)**

* Charge levels listed are approximate. Actual conditions vary 
depending on battery condition and load. ** Inverter shutdown 
protects battery against damage due to excessive discharge.

Fault Condition

LEDs

Fault 

Illuminated

Condition

All three lights 

Excessive discharge 

flash slowly*

(Inverter shutdown)

All three lights 

Overcharge (Charger 

flash quickly**

shutdown)

*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown
protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼
second off. Charger shutdown protects battery against damage due to overcharge. May also
indicate a battery charger fault exists. See Troubleshooting section.

“CHRG CURR” LED Function Chart (2012 and 3012 models only) 

Approximate Charge Rate Indication

LEDs
Illuminated

Charge Rate

All three lights on

Overcharge  
error*

Red

75% - 100%

Red & Yellow

50% - 75%

Yellow

25% - 50%

Green

0% - 25%

All three lights off

0%

* If all three lights remain on, an internal fault may exist. Turn off and disconnect the unit.
Then, call Tripp Lite at (773) 869-1234 for assistance.

1

2

3

4

5

6

7

1

2

3

4

5

6

7

1

2

1

2

1

2

3

4

5

6

1

2

3

4

5

6

Resetting Your Inverter to Restore AC Power

Your Inverter may cease supplying AC power or DC charging power in
order to protect itself from overload or to protect your electrical
system. To restore normal functioning:

Overload Reset:

Switch operating mode switch to “OFF” and remove

some of the connected electrical load (ie: turn off some of the AC
devices drawing power which may have caused the overload of the
unit). Wait one minute, then switch operating mode switch back to
either “AUTO/REMOTE” or “CHARGE ONLY.” 

Output Circuit Breaker Reset: 

Alternatively, check output circuit

breaker(s) on the unit's front panel. If tripped, remove some of the
electrical load, then wait one minute to allow components to cool
before resetting the circuit breaker. See Troubleshooting for other
possible reasons AC output may be absent.

Summary of Contents for APS 2012 INT

Page 1: ...ng array of power tools Standard vehicle alternators and batteries however often can t keep up with the increased power demand When alternators recharge batteries at a slower rate than they are discha...

Page 2: ...user serviceable parts inside Potentially lethal voltages exist within the Inverter as long as the battery supply and or AC input are connected During any service work the battery supply and AC input...

Page 3: ...However for generator equipped trucks it provides crews with the option of quiet power See Utilize Automatic Generator Starter Capability in the Configuration section for details Hardwire AC Input Out...

Page 4: ...move the overload and let the unit cool You may then turn the operating mode switch to either AUTO REMOTE or CHARGE ONLY after it has adequately cooled BATT VOLT LED Function Chart All models Approxim...

Page 5: ...upplied cable see Pin Configuration Diagram Once attached the interface will allow the Inverter to automatically switch a vehicle generator on when connected battery voltage levels are low 11 6 VDC an...

Page 6: ...ernator if the engine is kept running Battery Selection optional 540 watts 12V 45 DC Amps 270 Amp Hours 55 Amps Inverter Rating 5 Hours Recharge STEP 1 Determine Total Wattage Required Add the wattage...

Page 7: ...durable enough to allow for vertical mounting as well if your vehicle compartment requires this configuration For vertical mounting the control panel of the Inverter should face up B A 750 1250 model...

Page 8: ...Main Ground Lug to the vehicle s chassis or earth ground See the Feature Identification section to locate the Main Ground Lug on your specific Inverter model All installations must comply with nation...

Page 9: ...onnected to inputs from a split 240V service when in inverter mode When the Inverter is receiving AC power it can supply connected loads with up to 20 amps of power on each circuit When the Inverter i...

Page 10: ...connected batteries AUTO REMOTE position However if an external charger is used to recharge the batteries you will need to manually reset the unit by moving the Operating Mode Switch to OFF for two se...

Page 11: ...11R...

Page 12: ...200511034 93 2511 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com 12R...

Reviews: