12
8. Operation
Additional UPS Status Icons
ECO MODE
When the UPS system detects a drop in load (<20W) on the master
outlet for approximately 3 minutes, it will turn off the “Controlled by
Master Outlet” outlets.
The 3-minute delay ensures the ECO outlets remain powered during a
reboot.
LOAD LEVEL /
OVERLOAD
The LOAD LEVEL / OVERLOAD METER continously reports UPS
output load level during AC and Battery Modes.
The meter reports 1-bar (0-24%), 2-bars (25-49%), 3-bars (50-74%),
4-bars (75-100%) and OVERLOAD conditions (4-BARS + “OVERLOAD”
logo and caption).
BATTERY CHARGE
LEVEL
The BATTERY CHARGE LEVEL METER continously reports condition
of the sealed lead acid battery system during AC and Battery
modes.
The meter reports 1-bar (0-24%), 2-bars (25-49%), 3-bars (50-74%),
4-bars (75-100%) and LOW BATTERY conditions (1-BAR + “LOW BATT”
caption).
AVR / AUTO-VOLTAGE
REGULATION
The AVR icon indicates the UPS is actively correcting low or high
utility voltage during AC Mode operation.
The UPS is capable of maintaining 120V +/-10% ouput to connected
equipment during undervoltages to 97V and overvoltages as high as
145V. Battery backup mode and battery charging capability are both
available when AVR is engaged.
REPLACE BATTERY /
BATTERY
DISCONNECTED
The REPLACE BATTERY icon indicates the UPS battery system
either requires replacement or is disconnected.
The alarm will also sound every 2 seconds.
SITE WIRING FAULT
The SITE WIRING FAULT indicator indicates electrical wiring
problems.
Have electrical wiring inspected for fault conditions by a qualified
electrician.
COLOR ICON
The COLOR ICON will display at various points during the
configuration of LED bar color options.
See the
LED Color Bar Setting P9-P12
section for more information of
this configuration-mode icon.
Display Module Status Icons
DISPLAY MODULE
WIRELESS
CONNECTION
PAIRED
The WIRELESS CONNECTION PAIRED icon displays as the removable
LCD Module is connected to the UPS via wireless connection.
DISPLAY MODULE
DOCKED
The DISPLAY MODULE DOCKED icon displays as the LCD Module is
reconnected to the UPS and a wired connection is made.
DISPLAY MODULE
BATTERY CHARGE
LEVEL
The DISPLAY MODULE BATTERY METER icon continuously reports
battery charge level for the miniature NiMH battery that powers the
removeable LCD Module.
The meter reports 1-bar (low), 2-bars (medium), 3-bars (high) and 4-bars
(full) charge level. This display flashes every 0.5 seconds to indicate
Abnormal display module charging.
Note:
Except when in UPS fault condition, the LCD backlight automatically shuts off if there is no action for 1 minute (30 seconds when
panel is removed from base).
ECO