Triplett RHT60 User Manual Download Page 5

 
 

Minimum (MIN) Maximum (MAX) Function 

 

The MIN/MAX mode allows the user to view only 
the lowest

 (

MIN

or highest

 (

MAX

readings.

 

Press the

 

MAX/MIN

 

button once and

 

MAX”

 

appears on the display. The LCD is now 
displaying the maximum humidity in the top 
display and the maximum reading of the selected 
parameter in the bottom display. The display will 
not change until a higher reading is registered.

 

Press the

 

MAX/MIN

 

button again and

 

MIN”

appears on the display

The LCD is now displaying the minimum humidity and the minimum second 
reading in the bottom display.

 The display will not change until a lower 

reading is registered. 
 

To exit the MIN/MAX mode, press and hold the

 

MIN/MAX

 button

 

for 2 

seconds until the

 

MAX”

 

or “

MIN”

 

icon disappears.

 

 

 
Note

Readings are automatically reset when switching from one 

display to the next (MAX to MIN).

 

 
 
Backlight 

Press and hold the light button ( 

 ) until the backlight comes on. To 

turn thebacklight off press and hold the light button ( 

 ) until the 

backlight turns off.

 

 

 

 

Automatic Power OFF 

 

The meter has a default setting that automatically shuts the meter off after 
10 minutes (indicated by the 

 symbol on the display. This battery saving 

feature can be disabled. To disable the auto power off function, simply 
press and hold the hold button 
 

Summary of Contents for RHT60

Page 1: ...recision Psychrometer 5 Commonwealth Ave 5 Commonwealth Ave Woburn MA 01801 Woburn MA 01801 Phone 781 665 1400 Phone 781 665 1400 Toll Toll Free 1 800 517 8431 Free 1 800 517 8431 Visit us at www Test...

Page 2: ...Off and MAX MIN reading Meter Description 1 Humidity and Temperature Sensor 2 LCD Display 3 Power ON OFF Button 4 MIN MAX Button 5 F C WBT Wet Bulb Dew Point button 6 HOLD Backlight Button Note The b...

Page 3: ...Humidity measurement appears in the top display 4 Pressing the F C WBT Dew Point button toggles the lower display between Temperature F Temperature C Dew Point C Dew Point F Wet Bulb C and Wet Bulb F...

Page 4: ...is now displayed Temperature measurements 1 To select the temperature measurement press the F C WBT Dew Point button until C or F appears in the lower right 2 Temperature is now displayed Data Hold Pr...

Page 5: ...ing in the bottom display The display will not change until a lower reading is registered To exit the MIN MAX mode press and hold the MIN MAX button for 2 seconds until the MAX or MIN icon disappears...

Page 6: ...hen the battery power falls low the battery symbol will appear on the LCD Replace the 9 Volt battery by removing the Philips head screw holding the rear battery compartment cover to access the battery...

Page 7: ...0o C 158 1 to 199 0o F Wet Bulb 0 to 80 C 32 to 176 F Calculated from RH and air Dew Point 30 to 100 C 22 to 199 F temperature measurements Display Dual LCD Response Time 30 seconds 90 of final value...

Page 8: ...ly to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or rel...