Congratulations on your purchase of the Triplett Model RHT60 Hygro-
Thermometer with Wet Bulb and Dew Point.. This device measures 
Humidity, Air Temperature, Dew Point temperature and Wet Bulb 
temperature. Advanced features include Data Hold, Auto Power Off, and 
MAX/MIN reading 

 

Meter Description 

 

 

1.  Humidity and Temperature Sensor 

 

2.  LCD Display 

 

3.  Power ON/OFF Button 

 
        4.   MIN/MAX Button 

 

5.  °F/°C/WBT (Wet Bulb)/Dew Point button 

 

6.  HOLD/Backlight Button 

 
 

 

Note: The battery compartment is located on the rear of the 

instrument 

 

Display Description 

 

 
 

1.  Relative Humidity % 

 

2.  Dew Point 

 

3.  Wet Bulb 

 
        4.   °F/°C 

5.  Temp/Wet Buld/ Dew Point Display 

 

6.  Maximum 
7.  Minimum 
8.  Low Battery Indicator 
9.  Hold 
10. RH% Measurement  
11. Auto Power OFF Indicator 
 

Summary of Contents for RHT60

Page 1: ...recision Psychrometer 5 Commonwealth Ave 5 Commonwealth Ave Woburn MA 01801 Woburn MA 01801 Phone 781 665 1400 Phone 781 665 1400 Toll Toll Free 1 800 517 8431 Free 1 800 517 8431 Visit us at www Test...

Page 2: ...Off and MAX MIN reading Meter Description 1 Humidity and Temperature Sensor 2 LCD Display 3 Power ON OFF Button 4 MIN MAX Button 5 F C WBT Wet Bulb Dew Point button 6 HOLD Backlight Button Note The b...

Page 3: ...Humidity measurement appears in the top display 4 Pressing the F C WBT Dew Point button toggles the lower display between Temperature F Temperature C Dew Point C Dew Point F Wet Bulb C and Wet Bulb F...

Page 4: ...is now displayed Temperature measurements 1 To select the temperature measurement press the F C WBT Dew Point button until C or F appears in the lower right 2 Temperature is now displayed Data Hold Pr...

Page 5: ...ing in the bottom display The display will not change until a lower reading is registered To exit the MIN MAX mode press and hold the MIN MAX button for 2 seconds until the MAX or MIN icon disappears...

Page 6: ...hen the battery power falls low the battery symbol will appear on the LCD Replace the 9 Volt battery by removing the Philips head screw holding the rear battery compartment cover to access the battery...

Page 7: ...0o C 158 1 to 199 0o F Wet Bulb 0 to 80 C 32 to 176 F Calculated from RH and air Dew Point 30 to 100 C 22 to 199 F temperature measurements Display Dual LCD Response Time 30 seconds 90 of final value...

Page 8: ...ly to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or rel...