Test Modes
There are (3) Modes of operation for this tester selectable by the switch at the
rear of the tester. The function modes are as follows:
T mode
: for detecting PSE status
N mode
: for determining NON-standard PoE + inline testing
I mode
: for testing and monitoring real time power status
Operation Notes
When performing Inline Testing in T-Mode connect to the PSE side of
the tester first .until voltage is displayed, then connect PD side.
The length of the cable and the quality of the cable or the pin location
in the RJ45 connector can affect the real power available. To ensure
the power at the other end of the wall outlet is what is required for PD
test the wattage level at the wall outlet/jack where the PD plugs in.
The STEP button allows you to select specific test data for easier
reading .Pressing this button once will change auto-rotate to step
mode, and voltage display will be the default measurement. Press the
button again to select current or power display.
To revert back to auto-rotate, disconnect the PSE side cable (If in
Inline Testing disconnect PD side cable first, then disconnect the PSE
Numeric LCD for Inline
Power Testing (U) Voltage,
(A) Current, (P) Power
STEP Button cycles:
Voltage
Current
Power