Test Modes 

 

There are (3) Modes of operation for this tester selectable by the switch at the 
rear of the tester. The function modes are as follows: 

 
T mode

: for detecting PSE status 

N mode

: for determining NON-standard PoE + inline testing 

I mode

: for testing and monitoring real time power status 

 
 

Operation Notes 

 

 

When performing Inline Testing in T-Mode connect to the PSE side of 
the tester first .until voltage is displayed, then connect PD side. 

 

 

The length of the cable and the quality of the cable or the pin location 
in the RJ45 connector can affect the real power available. To ensure 
the power at the other end of the wall outlet is what is required for  PD 
test the wattage level at the wall outlet/jack where the PD plugs in. 

 

 

The STEP button allows you to select specific test data for easier 
reading .Pressing this button once will change auto-rotate to step 
mode, and voltage display will be the default measurement. Press the 
button again to select current or power display. 

 

 

To revert back to auto-rotate, disconnect the PSE side cable (If in 
Inline Testing disconnect PD side cable first, then disconnect the PSE 

Numeric LCD for Inline 
Power Testing (U) Voltage, 
(A) Current, (P) Power  
STEP Button cycles: 
 Voltage 

Current

Power 

 

 