Triplett MS475 User Manual Download Page 10

 
 

Operating Humidity 

90%, 32-86°F (0-30°C), 75%, 86-104°F (30-40°C), 

 

45%,104-122°F(40-
50°C) 

 

 

Storage Humidity 

90% 

  

 

Power Supply 

9V battery 

 

 

Battery Life 

6-8 weeks (4 hrs/day use), using alkaline batteries 

Auto Power Off 
(APO) 

After 30 minutes (nominal) inactivity. The APO function 
can be disabled 

 

by the user. 

 

 

APO Quiescent 
Current 

50µA maximum 

 

 

Dimensions 

9.6 x 2.8 x 1.8” (245 x 
70 x 45mm) 

 

 

Weight 

8.5oz (240g) 

 

 

 
 
 
 
 
Warranty Information 

Triplett / Jewell Instruments extends the following warranty to the original purchaser of 
these goods for use. Triplett warrants to the original purchaser for use that the products sold 
by it will be free from defects in workmanship and material for a period of (1) one year from 
the date of purchase. This warranty does not apply to any of our products which have been 
repaired or altered by unauthorized persons in any way or purchased from unauthorized 
distributors so as, in our sole judgment, to injure their stability or reliability, or which have 
been subject to misuse, abuse, misapplication, negligence, accident or which have had the 
serial numbers altered, defaced, or removed. Accessories, including batteries are not 
covered by this warranty 

Copyright © 2020 Triplett 

www.triplett.com 

 

Summary of Contents for MS475

Page 1: ...lus IR Thermometer Monitor moisture in wood and other building materials with no surface damage with the Pinless Moisture sensor Pin type Moisture Probe included Measure Humidity and Air Temperature w...

Page 2: ...COND Condensation Button 5 RH Relative Humidity Button 6 MOIST REL Button 7 DOWN ZERO Button 8 UP UNIT Button 9 Memory Store Enter ALARM Set Button 10 IR Thermometer Button 11 ON OFF Button 12 Pinles...

Page 3: ...tion 6 Low battery indication 7 GPP unit indication Grains Per Pound 8 MAX MIN indication 9 Condensation mode symbol 10 VPP unit indication Vapor Pressure 11 GPP unit indication 12 Humidity bar displa...

Page 4: ...ure plus Grains Per Pound GPP and Dew Point DP Ambient and Surface Vapor Pressure Automatic calculation of differential Temperature IR DP Min Max and Data Hold 20 point internal memory Auto power off...

Page 5: ...e and to return to the normal mode 6 If the humidity measurement is higher than the LOW alarm setting the meter will beep once every second 7 If the humidity measurement is higher than the HIGH alarm...

Page 6: ...r approximately 10 seconds before returning to ambient temperature measurement IRT MAX MIN display The meter can be set to display only the maximum or minimum temperature measured during an IR scan 1...

Page 7: ...ew Point the temperature difference shall be displayed with no other warning If the temperature of the IRT is 3 14 C 5 25 F above the Dew Point the temperature difference shall be displayed along with...

Page 8: ...ay stored readings The numeric display above the MEM icon will flash 2 Use the or button to scroll through the memory locations 3 To return to normal operating mode press the STORE button Clearing Sto...

Page 9: ...to 1 C 9 F 5 C D S 8 1 32 F 0 C 1 8 F 1 C Emissivity 0 95 Fixed 33 to 392 F 1 to 200 C 3 6 F 2 2 C Display 3 digit primary display 4 digit secondary display Vapor Pressure 0 to 20 0kPA calculated fro...

Page 10: ...hese goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of 1 one year from the date of pu...

Reviews: